Software
Descaling
Insert the water tank with the filled in descaling
solution and confirm on the display
Descaling starts. This part of the routine takes about
40 min.
Remove water tank and empty out remaining
descaler solution
Rinse water tank and fill to maximum
Replace water tank
Rinse
Rinsing commences. After the initial rinse is emptied
from the water tank the display requests that the water
supply be turned on again. This part of the routine takes
about 40 min.
Turn on mains water tap
Leave the water tank in place. The water tank connector
is rinsed for approximately 10 seconds from the mains
supply.
Remove water tank and dry
Replace and tighten seal plug on water tank
connector in an clockwise direction (screwdriver).
See illustration.
Replace water tank
Subsequent rinses are from the mains supply.
After the final rinse the steam boiler is heated. The hot
water expands and finally exits briefly as steam.
Descaling is complete. Completion is indicated on the
display.
Filter Change
If the filter capacity is exceeded there will be a
message once per day that a filter change is due.
The filter must be changed within one week otherwise
the message will be displayed after every brew.
Change filter
Confirm filter change
After filter change there is an automatic program
sequence to rinse and bleed the anti-scale filter and
water system.
Caution!
Hot Steam!
Observe the Safety chapter!
Observe anti-scale filter
instruction!
Displays lead step by step
through the program. Follow
instructions!
Caution!
Scald hazard
Observe the Safety chapter!