Summary of Contents for 9800+

Page 1: ... Scantronic Leading the way in security ...

Page 2: ...emote Reset 11 4 Special Functions 12 Introduction 12 Omitting Zones 12 Omitting 24 Hour Zones 13 Setting the Time and Date 13 Access Codes 14 Duress Code 14 Changing Access Codes 14 Using the Log 15 Table 1 Log Event Codes 15 Table 1 Cont d Log Event Codes 16 Turning the Chime On Off 16 Testing the System 16 Bell Test 16 Walk Test 17 5 System Faults 18 9800 16 Zone Hardwired Control Panel User Gu...

Page 3: ...raise an alarm if a detector is triggered The system provides three different setting Levels labelled A B and C Level A sets the whole system protecting all of the premises covered by the alarm system Levels B and C set part of the system protecting part of the premises while the rest is in use The system raises an alarm when a detec tor belonging to a set Level is triggered The Installer programs...

Page 4: ...glows when the system is in alarm if the system has detected a fault on the telephone line or if the internal battery has failed Service LED The Service LED glows when the panel needs an engineer to reset it or the system has detected an internal problem Call your alarm installer Power LED The Power LED glows when the system is using mains power If the Power LED flashes slowly then the mains power...

Page 5: ...e X key Omit on 9800 keypads lets you omit bypass zones when setting the system Note that the Installer must program individual zones so that the system will allow you to bypass them Clear The key Clear on 9800 keypads tells the system that you have finished entering an access code or other command see 4 Special Functions About This Guide The rest of this guide tells you how to use the system in m...

Page 6: ...f the Power LED is dark then the system is dead When the system is set a Level LED glows to show which Level key was used When the system is unset the Day LED glows However the Installer can program the system to hide these displays Ask your installer how the system is set up If you wish to test the system and its detectors see 4 Special Functions Testing the System Setting the System Timed Final ...

Page 7: ...me 1 Close all doors and windows 2 Key in your access code at the keypad 3 Press the appropriate Level key The keypad starts the continuous exit tone and the Level LED flashes 4 Leave via the designated exit route and close the final door Exit Terminate Button Set In Exit Terminate Button setting the system completes setting after you press a button mounted outside the premises by the final door 1...

Page 8: ...rotected by a part set system may not need an exit route or final exit door For these areas the Installer may program the Level key protecting the area as Instant Set With Instant Set the system sets as soon as you press the Level key Note that Instant set is only available on level keys B and C Keyswitch Setting 1 Close all doors and windows The Ready lamp on the keyswitch should be glowing to in...

Page 9: ...gnated entry door and go to the keypad As you enter the premises the system starts the entry timer and the keypad gives the entry tone 2 Key in your access code at the keypad The entry tone stops The system is now unset If You Exceed the Entry Time If you regularly have problems exceeding the entry time ask your installer about Dual Ply Entry and Alarm Abort If the system is programmed for Dual Pl...

Page 10: ...d Fault LEDs glow and the display shows the letter c with the zone number of the first detector to be triggered You may also see the Service LED glowing 3 Establish the cause of the alarm 4 Carry on to reset the system Resetting the System There are three different methods for resetting You can tell which method your system uses by looking at the Service LED after an alarm If the Service LED is da...

Page 11: ...e two pairs of numbers make a four digit Control Code 4 Write down the four digit Control Code Note that the system will display the control code twice and then return to showing the first detector to alarm If you miss the Control Code repeat steps 1 to 3 5 Contact your alarm company central station The central station will ask a few questions to make sure you are who you say you are They will the...

Page 12: ...you can omit individual detectors when setting the system Ask your Installer which zones can be omitted Note that omission is not permanent You must omit the zone every time you set the system To set with a zone omitted 1 Key in your access code 2 Press the appropriate Level key and then within 5 seconds 3 For zones 1 to 9 press X Omit followed by the number s of the zone s you want to omit for ex...

Page 13: ...lendar that runs as long as there is power present mains or stand by battery The system uses this clock to mark the time and date on the system log If the power supply fails for any reason and the stand by battery is low then the system loses track of the correct time and date You may also need to change the time if you live in an area that uses summer winter time Note You need the access code for...

Page 14: ...default access code is 1234 You should change this immediately to a code that only you know User 02 default access code is X 002 User 03 is X 003 and so on up to User 08 X 008 However the default access codes for these users cannot set or unset the system or use any of its special functions On older key pads use the OMIT key in place of the X key Duress Code If your system is connected to a centra...

Page 15: ...earlier events in the log Press 3 to see more recent events The display shows a two character code for each type of event Table 1 on the next page shows each of the codes that you might see and their meaning 4 Press Clear twice to stop using the log Table 1 Log Event Codes Code Meaning AA Arm area A full set Ab Arm area B part set Ac Arm area C part set AE Installer access AP Auxiliary power failu...

Page 16: ...letter c and the number of the zone Turning the Chime On Off Your system may be programmed so that a chime tone sounds whenever certain doors are opened while the system is unset If your system has an Exit Terminate button then it will act as a door bell while Chime is on To turn Chime on or off 1 Key in your access code The display shows _ _ 2 Press 7 followed by Clear Testing the System Bell Tes...

Page 17: ...h 24 hour or personal attack detectors you cannot walk test them If you wish to test them call your alarm company 1 Key in your access code The display shows _ _ 2 Press 9 The display shows then C and the zone number of any detector s that are already triggered 3 Walk round your premises and trigger each detector in turn except 24 hour or personal attack detectors As you trigger a detector the key...

Page 18: ...y alarms to the central monitoring station until the telephone line is repaired bF Battery fault Enter your access code to silence the sounder Contact your alarm company immediately You cannot set the system until the fault is cleared Lb Battery Low Enter your access code to silence the sounder Contact your alarm company immediately You cannot set the system until the fault is cleared Sr Total pow...

Page 19: ...Day contact Tel Night contact Tel Company Name 496247 Issue 4 19 ...

Page 20: ...20 496247 Issue 4 ...