Maximum angles of inclination during operation
Maximum permissible angles during operation vary, depending on the type of
oil sump, see illustration.
Note:
The specified angles may only occur periodically.
30°
24°
26°
30°
15°
15°
3. Every 400 hours:
Cleaning the centrifugal oil cleaner
(At the same time as an oil change)
- Clean the cover. Unscrew the nut and remove the cover.
01_1288
Open the cover carefully. The
oil may be hot.
WARNING
!
- Lift out the rotor and loosen the nut on the rotor cover 3 turns.
- If the nut is jammed:
Clamp the nut,
but never the rotor
, in a vice and turn the rotor 3 turns by
hand or with a screwdriver.
- Tap the nut lightly with your hand or a plastic hammer, to detach the
rotor cover from the bottom plate.