© Scania Industrial & Marine Engines
15
Action in case of a fault
LED indications in case of a fault
Note
The main indicator lamp in the main supply
box and at the instrument panel has
indicated a fault. The lamp test/fault code
switch should not be depressed.
CONTROL STATUS
✹
The LED will continue to flash even in case of a
fault as long as voltage is supplied to the control
unit.
POWER
-
✹
If the LED comes on, the control unit has
detected a defect that could cause damage to the
engine if operation continues.
The control unit automatically reduces engine
power output to a predefined level if the
corresponding function has been selected.
Action: Reduce engine speed to idle if possible
and conduct troubleshooting according to
instructions on page 16 and the chart on page 17
SHUTDOWN
✹
The LED comes on and the engine is switched
off automatically in case of a severe fault that
could cause damage to the engine if operation
continues.
Action: Conduct troubleshooting according to
instructions on page 16 and the chart on page 17
If the engine has not stopped, reduce engine
speed to idle and conduct troubleshooting.