13
1. INTRODUCTION
This manual was created to help you install and learn all about the functional possibilities of the NCS scale.
WARNINGS
The scales should be sited in a location that will not degrade the accuracy.
Avoid extremes of temperature. Do not place in direct sunlight or near air conditioning vents.
Avoid unsuitable tables. The tables or floor must be rigid and not vibrate. Do not place near vibrating machinery.
Avoid unstable power sources. Do not use near large users of electricity such as welding equipment or large motors.
Avoid high humidity that might cause condensation. Avoid direct contact with water. Do not spray or immerse the scales in
water.
Avoid air movement such as from fans or opening doors. Do not place near open windows.
Keep the scales clean.
Do not stack material on the scales when they are not in use.
2. MAIN TECHNICAL SPECIFICATIONS
Model
Plate
(dimensions in mm)
Capacity kg
Division g
Resolution g
CE-M Division g
NCS3K
218x267
3
0,1
0,01
1
NCS6K
218x267
6
0,2
0,02
2
NCS15K
218x267
15
0,5
0,05
5
NCS30K
218x267
30
1,0
0,10
10
Operative Temperature:
0°C - 40°C / 32°F - 104°F.
Relative humidity:
≤ 85 % RH
Power supply:
AC 240V (±10%) / 50 Hz, 110V/60HZ
DC 4V / 4Ah with rechargeable accumulator inside.
Zero range:
+/- 2% of max load capacity.
Auto zero at start-up:
+/- 10% of max load capacity.