19
6.6 DISPLAY BACKLIGHT
By keeping pressed the
ZERO-B.L.
key, the display will scroll the possible activation modes; release the key when the
desired functioning is displayed:
OFF
backlighting always off
ON
backlighting always on.
AUTO
backlighting on when the weight is unstable or when a key is pressed. The backlighting remains active for 5
seconds.
7. MESSAGES
MESSAGES
DESCRIPTION
RESOLUTION
- - OF - -
Over range
Remove weight from the scale.
Err 2 / ZERO
Zero Error
Upon start-up or when the
ZERO
key is pressed, the weight on the
scale exceeds the +/- 10% of the max. capacity.
Remove the excess weight and retry.
UNSTA
Auto Zero Error
Upon start-up, the weight on the scale is not stable to be zeroed. It
maybe because of the platform’s intensity is too low or the platform is
shaken strongly.
You may strengthen the platform or avoid the shake.
- - ADC - -
Input signal
overflow error
Indicates that the A/D converter value is overflows:
- Remove the weight from the scale if it’s exceeding.
- The load cell or the electronics could be damaged.
- SYS -
Calibration error
Please re-calibrate the scale with the procedure with zero acquisition
(see section 6.3). If the problem persists contact the dealer.
- LO -
Accumulator
voltage low
One can use the scale in a short time, but you should plug in the AC
plug as soon as possible to recharge the accumulator.
- - AC - -
Accumulator
recharge.