![Scaime eNodTouch-M Instruction Manual Download Page 46](http://html1.mh-extra.com/html/scaime/enodtouch-m/enodtouch-m_instruction-manual_1206006046.webp)
46
User manual SCAIME:
NU-eNodTouchM-E-0815_196774-B
3.7.4.
In-flight correction Settings
Parameter Possible
Value
Description
In-flight correction parameters
Page 1/2
Automatic correction
[Yes], [No]
If enable, In-flight level is automatically corrected at each end of cycle.
In-Flight weight Level
±500 000
In-flight Level corresponds to the weight of product that carries on falling
after the FF output is disabled. Its value can be automatically corrected.
Min / Max In-Flight
level
±32768
Min In-flight Level < In-flight Level < max In-flight Level. If this condition is
not satisfied, In-flight is not changed.
If these levels are zero, there is no control of limits. But regardless of these
limitations, the value calculated automatically is limited to FF level.
Page 2/2
Correction %
0 – 100 %
If Automatic correction enabled, the correction formula is:
In-flight = In- (Dosing result – Target weight) x Correction %.
X3 correction if Out
of Tolerance
[Yes], [No]
If the Dosing result is out of Tolerance, ‘Correction %’ is multiplied by 3
(limited at 100 %) inside the correction formula.