User manual SCAIME:
NU-eNodTouchM-E-0815_196774-B
3.7.2.
Starting conditions setup
Parameter Possible
Value
Description
Starting Conditions
Filling mode Unloading mode
Filling mode
Min. empty weight
± 500 000
Allow empty packing presence verification at the start of cycle: Min empty
weight < Gross measurement <Max empty weight.
If Min empty weight = Max empty weight = 0: No verification
Max. empty weight
Automatic start
[Yes], [No]
Filling cycle starts automatically when the gross weight is between the
'Min. empty weight' and 'Max. empty weight'.
Unloading mode
Residual weight
0
–
1
000
000
eNod4-D refuse ‘start cycle’ and reports a dosing error if gross
measurement < (target residual weight).