7.2. Back face

The SplitBox back face is used to connect the Ekinox or the Apogee. It will have either 3 connectors for the
STD version or one connector for SUB versions. In both cases there is also the 

Power In

 connector that will

supply both the Split box and the Ekinox.

7.2.1. Power In

The connector is a Fischer Connectors Alulite receptacle similar to the one used on the Ekinox and Apogee
devices.

Its reference is: AL1731-DBPU-103-Z051PB11-12G13

Pin #

Name

Description

Shield

Shield

Mechanical ground

1

Vin+

Power input

2

Vin-

Power ground

7.2.2. Standard SplitBox, Ekinox/Apogee connectors

7.2.2.1. Ekinox/Apogee Power Supply

The connector is a Fischer Connectors Alulite receptacle similar to the one used on the Ekinox and Apogee
devices but with a reversed polarity for obvious safety reasons.

Its reference is: AL1731-DBPU-103-A051PB11-12G13

Pin #

Name

Description

Shield

Shield

Mechanical ground

1

Vin+

Power input

2

Vin-

Power ground

21/30

Summary of Contents for SplitBox

Page 1: ...ox Interfacing with Ekinox and Apogee User Manual intro Document SPLITBOXUM 1 2 Revision 1 2 May 14 2018 Support EMEA support sbg systems com 33 1 80 88 43 70 Americas support sbg systems com 1 657 54...

Page 2: ...1 1 Jun 9 2016 Alexis Guinamard SPLITBOXUM 1 Update support contact details 1 Feb 25 2015 Nicolas Michel First version of this document 2007 2018 SBG Systems SAS All rights reserved Information in thi...

Page 3: ...Version Standard STD 11 4 2 2 Version Subsea SUB 11 4 3 Status LED Description 12 4 3 1 Power LED 12 4 3 2 Satellite LED 12 4 3 3 Sync Out LED 12 4 3 4 Network LED 12 4 4 Configuration Switches 13 5...

Page 4: ...Supply 21 7 2 2 2 Ekinox Apogee Main 22 7 2 2 3 Ekinox Apogee Auxiliary 23 7 2 3 Subsea SplitBox Ekinox connector 24 8 Support 26 9 Appendix A Accessories 27 9 1 Cables 27 9 1 1 CA AEK PWR PSU 1 5M 2...

Page 5: ...u should only look to the appropriate section of this document for your specific SplitBox SplitBox ordering code Description SPLITBOX STD Standard surface without GNSS receiver SPLITBOX STD S Standard...

Page 6: ...PS L1 L2 L2C L5 GLONASS L1 L2 L2CA Galileo E1 E5ab E6 Beidou B1 B2 B3 SBAS QZSS Galileo and Beidou signals are available in option Horizontal position accuracy Single point L1 L2 L5 1 0 m PPP support...

Page 7: ...PS L1 C A L2E L2C L5 GLONASS L1 C A L2 C A L2 P L3 CDMA Galileo 1 BOC E5A E5B E5AltBOC Beidou B1 B2 SBAS QZSS L Band OmniSTAR VBS HP XP Galileo and Beidou signals are available in option Horizontal po...

Page 8: ...sn t support CAN communications In addition the Sync In C is not available for subsea units 2 2 SplitBox with GNSS models S or T On the SplitBox equipped with an internal GNSS receiver the connections...

Page 9: ...PORT D Tx is always connected to the internal GNSS receiver COM 1 This is very useful if you would like to use the PORT D to input RTCM corrections while sending GGA frames 1 Hz from the GNSS receiver...

Page 10: ...es the different connectors and indicators available on the SplitBox 4 1 Front face This face brings one connector for each port of the Ekinox Apogee The Ethernet PORT A B C E and CAN connectors are l...

Page 11: ...the bottom right corner an eight ways configuration switch is used to change the SplitBox behavior Finally for SplitBox with an internal GNSS receiver the Main and Secondary GNSS antennas can be conn...

Page 12: ...valid position and red when entering RTK mode 4 3 3 Sync Out LED This LED reflects the signal present on the Sync Out B Note Please not that the default Sync Out B signal level is HIGH If no Sync Out...

Page 13: ...below Switch Position Function Switch UP Switch DOWN Comment Top Row T 1 Port A Protocol RS 232 RS 422 2 Port B Protocol RS 232 RS 422 3 Port C Protocol RS 232 RS 422 4 Port D Protocol RS 232 RS 422 B...

Page 14: ...2 9 x 58 mm 7 5 x 6 42 x 2 3 including connectors Weight STD 1310g STD S 1420g STD T 1435g SUB 1310g SUB S 1420g SUB T 1435g Enclosure Extruded Aluminum Die casted Zinc alloy IP Rating IP65 Operating...

Page 15: ...SplitBox User Manual SPLITBOXUM 1 2 5 2 3 Back view 5 2 3 1 Version Standard STD 5 2 3 2 Version Subsea SUB 15 30...

Page 16: ...nd 6 2 I O Electrical Specifications Parameter Min Typ Max Units Conditions Port A B C D E Sync In Input Voltage Range 25 25 V Input Threshold 0 8 1 5 1 8 2 7 V V Threshold Low Threshold High Input Hy...

Page 17: ...oltage for Complementary Output States 0 2 V Output Short circuit Current 250 mA 7V TX or TX 12V ESD Protection 15 kV Human Body Model Port A B C D E RS 232 Receiver Receiver Data Rate 4800 921600 bps...

Page 18: ...nnector There is no termination resistor between CAN_L and CAN_H Pin Name Description 2 CAN_L CAN bus 2 0 low line 3 GND 7 CAN_H CAN bus 2 0 high line 7 1 3 Port A This full duplex PORT A can either b...

Page 19: ...radio modem selectable via configuration switch 5 GND GND Ground return 6 NA Rx In 7 1 5 2 SplitBox with GNSS RTCM input GPS configuration Special serial port used to input RTCM corrections or to get...

Page 20: ...Sync In Signal GPS PPS for example 2 Rx Rx In 4 PWR PWR Out 12V output to provide power to a third party equipment such as an odometer selectable via configuration switch 5 GND GND Ground return 6 NA...

Page 21: ...to the one used on the Ekinox and Apogee devices Its reference is AL1731 DBPU 103 Z051PB11 12G13 Pin Name Description Shield Shield Mechanical ground 1 Vin Power input 2 Vin Power ground 7 2 2 Standa...

Page 22: ...ical ground 2 GND Connected to GND to select RS 422 mode 3 Sync Out A Synchronization output signal A 4 Sync Out B Synchronization output signal B 6 Sync In A Synchronization input signal A 8 Port A R...

Page 23: ...tion 12 Port B RS 422 Rx Port B serial input RS 422 13 Port B RS 422 Rx Port B serial input RS 422 14 Port B RS 422 Tx Port B serial output RS 422 15 Port B RS 422 Tx Port B serial output RS 422 6 Syn...

Page 24: ...main connector electrical ground 15 GND Connected to the main connector electrical ground 16 Sync In B Port B input synchronization 17 Port A RS 422 Tx Port A serial output RS 422 18 Port A RS 422 Tx...

Page 25: ...42 GND Connected to the main connector electrical ground 43 GND Connected to the main connector electrical ground 44 GND Connected to the main connector electrical ground 45 GND Connected to the main...

Page 26: ...ith the use of your product we would be glad to help you so feel free to contact us EMEA SBG Systems S A S 1 avenue Eiffel 78420 Carri res sur Seine FRANCE Phone 33 1 80 88 43 70 support sbg systems c...

Page 27: ...external power supply 1 x Fischer Core Series S 103 Z051 130 connector 1 x open end IP 68 rating 3m long AWG 18 cable Weight 170g Cable wiring is Pin Signal Color SHIELD NC SHIELD 1 V Red 2 V Black 9...

Page 28: ...104 A092 130 IP 68 rating 5 m AWG26 shielded cable with twisted pairs Weight 500g 9 1 5 CA AEK AUX SB 5M Cable used to connect the AUX connectors from a surface SplitBox to a surface Ekinox or Apogee...

Page 29: ...on Resistance Rating Core to Core 900 M km 500 V Core to Screen 500 M km 500 V Screen to Screen 10 M km 500 V 26 AWG Screen Twisted Paris Signals Nominal Conductor Resistance 181 10 km 20 C Nominal Im...

Page 30: ...Beidou Pole Mount TNC Connector Excellent multipath rejection Dimensions 146mm h 62 5mm Weight 420g 9 2 2 TNC Cables The following TNC cables can be ordered to connect the SplitBox with integrated GNS...

Reviews: