MW-1000™ User Guide
24
0 = False
1 = True
RandTemporaryID
0
0, 1
Randomize the J2735 Temporary ID with a
certificate change.
0 = False
1 = True
RandMsgCount
1
0, 1
Randomize the J2735 message count with
a certificate change.
0 = False
1 = True
Logging Configuration Items
LogFileFormat
0
0, 1
0 = Disabled
1 = Enable
TxLogEnableFlag
1
0, 1
Support slogging of the Tx log data.
0 = Disabled
1 = Enable
RxLogEnableFlag
1
0, 1
Supports logging of the Rx log data.
0 = Disabled
1 = Enable
StatsLogEnableFlag
1
0, 1
Support logging of the stats log data.
0 = Disabled
1 = Enable
CertLogFileFlag
1
0, 1
Supports logging of full certificate and
corresponding SHA-256 raw data.
0 = Disabled
1 = Enable
Data Source Configuration Items
BSMTxDataSource
1
1, 5
1 = Live data
2 = Prerecorded file
3 = UDP source
4 = GPS only
5 = Hybrid
AsyncGPS
1
0, 1
Parameter
Value
Range
Description
1609.3 Filter Mode Options
FilterMode
0
Enable/Disable filter mode
RSUAdvertiserID
USDOT
RSUSelectionAlgorithm
0
0,1
0 - Distance based algorithm
1 – Unsupported
RSUDistanceThreshold
150
0, 300
absolute distance in meters to avoid
connecting, and disconnecting when
the OBU is going away from the RSU