KDB-GOM
Series
- 54 -
Switch DIP switch #5 (“B”) on the main controller to the new settings
Table 2
.
■
L.P. Gas
: DIP switch # 5 "ON"
■
Natural Gas : DIP switch # 5 "OFF"
[Fig. 1] Procedure of gas conversion
[Table 2] DIP switch setting on the main controller
[Table 3] Gas modulating valve head(
㎜
㎜
㎜
㎜
H
2
O)
No
ON
OFF
1
Trial operation
Normal
2
Forced Max. Combustion
Normal
3
Forced Min. Combustion
Normal
4
F.E
F.F
5
L.P Gas
Natural Gas
6
Sealed combustion
Open Combustion
7
50 Hz
60 Hz
Gas Modulating head Pressure , mmH
₂
₂
₂
₂
O(inch W.C.)
Max. Load
Min. Load
Front Panel
ON
Front Panel
OFF
Front Panel
ON
Front Panel
OFF
KDB-161GOM-NG
Natural Gas
100 (3.94)
104 (4.10)
16 (0.63)
18 (0.71)
φ
1.33 (0.052)
161GOM-LP
L.P. Gas
170 (6.70)
174 (6.86)
26 (1.02)
28 (1.10)
φ
0.92 (0.036)
KDB-201GOM-NG
Natural Gas
104 (4.10)
108 (4.26)
16 (0.63)
18 (0.71)
φ
1.46 (0.057)
201GOM-LP
L.P. Gas
150 (5.91)
154 (6.07)
26 (1.02)
28 (1.10)
φ
1.06 (0.041)
KDB-251GOM-NG
Natural Gas
104 (4.10)
110 (4.34)
20 (0.79)
22 (0.87)
φ
1.37 (0.053)
251GOM-LP
L.P. Gas
164 (6.46)
170 (6.70)
24 (0.95)
26 (1.02)
φ
0.95 (0.037)
KDB-301GOM-NG
Natural Gas
106 (4.18)
116 (4.57)
20 (0.79)
22 (0.87)
φ
1.50 (0.059)
301GOM-LP
L.P. Gas
156 (6.15)
166 (6.54)
28 (1.10)
30 (1.18)
φ
1.06 (0.041)
- Key -
①
Igniter wire & Ignition sensor
③
Ignition Transformer
②
Combustion chamber
④
Nozzle Assembly