background image

 

 

Specifications

 

Model 

No. 7200-00 

No. 7202-00 

Number of pens 

1 pen 

2 pens 

Cylinder clock 

Quartz Type 

Measuring Range 

-15 to +50

 

Measuring method 

The movement of bourdon tube 

Recording period 

7 day and 32 day 

7 day 

Lead wire 

5m covered with vinyl 

5m covered with vinyl for each 

Sensing bulb 

Plain connection w/o thread type (stainless steel) 

Accuracy 

±

1

 

Min. graduation 

1

 

Recording pen 

Cartridge pen (violet) 

Dimensions 

336(W) x 148(D) x 295(H) mm 

Weight 

3.8kgs 

4.7kgs 

Accessories 

1 pad (55 sheets) of 7-day chart, Chart holder, 2 manganese batteries 

 

Consumable 

No. 7200-62: 1 pad (55 sheets) of 7-day chart for No. 7200-00 

No. 7200-64: 1 pad (55 sheets) of 32-day chart for No. 7200-00 

No. 7202-62: 1 pad (55 sheets) of 7-day chart for No.7202-00 

No. 7210-90: Cartridge pen (violet) for No. 7200-00 and No. 7202-00 

No. 7210-92: Cartridge pen (red) for no. 7200-00 and No. 7202-00 

 

WARRANTY POLICY 

Warranty 

Our products are warranted to be free from defects in materials and workmanship for a period of one 

year from date of delivery.    If repair or adjustment is necessary and has not been the result of abuse or 

misuse within the one-year-period, please return the units on - Freight Prepaid 

– basis and correction of 

the  defect  will  be  made  without  charges.    We  alone  will  determine  if  the  product  problem  is  due  to 

deviations or customer misuse. - Out-of-warranty products will be repaired on charge basis - 

Warranty during transportation 

The  warranty  during  transportation  only  applies  to  the  products  that  we  arrange  the  shipment.    The 

case that the

 

products had been purchased in domestic and were sent to overseas by the purchaser 

is out of warranty. 

Return of items 

Authorization  must  be  obtained  from  us  before  returning  items  for  any  reason.  When  applying  for 

authorization, please include data regarding the reasons the items are to be returned.     

 

Please note that we reserve the right to make improvements in design, construction and appearance of 

our products without notice.                                                                                                                        J.01

 

Summary of Contents for 7200-00

Page 1: ...Instruction Manual No 7200 00 Remote One Point Thermograph No 7202 00 Remote Two Point Thermograph ...

Page 2: ...transportation After unpacking place the unit in a stable atmosphere for one hour or more and confirm that the indicated valued is within the specified accuracy by comparison with the reliable thermometer If the indicated value is out of accuracy specified adjust the value referring to the Indication adjustment If there are anything unclear contact us or the dealer who purchased the unit from Proc...

Page 3: ...tside Insert batteries and close the lid 6 Insert two batteries and close the lid 7 Remove chart holder 8 Change chart 9 Attach chart holder 10 Mount recording cylinder 11 Attach cylinder holding nut 12 Lift pen holding clip and remove it ...

Page 4: ...ing it counterclockwise 14 Push pen lifting lever away from you until it stops 15 Set time 16 Turn carrying handle to the left and position the cover securely 17 Turn carrying handle clockwise until stops 18 Insert the sensing bulb into object ...

Page 5: ... Wind the new chart onto the cylinder so that the end of the paper will be put on the start of the chart Secure the overlapping section with the chart holder Make sure the markings the chart are aligned where the overlap occurs and the lower edge of the chart is against the bottom lip of the drum Setting the time Turn the cylinder counterclockwise to set the present time Turning the cylinder clock...

Page 6: ...ur instruments and we cannot guarantee the same accuracy with any other paper nor cartridge pen Do not repair the instrument by yourself Should repairs be necessary please return the instrument to the place of purchase Indication adjustment We calibrate the instrument at our factory so it is not necessary for you to make any other adjustments before use if some adjustment is required however follo...

Page 7: ...en the LED lamp goes out replace batteries to new ones NB Recording cylinder stops in one month after the LED lamp goes out Changing cylinder speed The cylinder speed switch is set for 7 day operation when shipped from the factory Set the switch at the top of cylinder clock to 32D for 32 day operation and change the chart to 32 day chart Cylinder speed switch 1 day operation of both model and 32 d...

Page 8: ... Our products are warranted to be free from defects in materials and workmanship for a period of one year from date of delivery If repair or adjustment is necessary and has not been the result of abuse or misuse within the one year period please return the units on Freight Prepaid basis and correction of the defect will be made without charges We alone will determine if the product problem is due ...

Reviews: