Page 1: ...at ti io on n M Ma an nu ua al l Infrared Camera I IR R C CA AM M 1 16 60 0 PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION 3 Hagavish st Israel 58817 Tel 972 3 5595252 Fax 972 3 5594529 mrc mrclab...

Page 2: ...red Camera Please read this user manual carefully before first use Also please keep in a safe place for reference in the future Please operate with the recommended instructions in user manual We reser...

Page 3: ...iolent shock and impact during operation or transport Storage temperature is between 40O C and 70O C The device must be kept in original packing case during transport Typical storage place is cool dry...

Page 4: ...face Panel 6 3 3 Side View 8 4 Quick Start Reference 8 4 1 Infrared Image 8 4 2 Measure Target Temperature 9 4 3 Infrared Image and Voice Annotation 9 4 4 Infrared Image Playback 10 4 5 Replace Lens 1...

Page 5: ...Unit 30 Ambient Temp 30 Reference 30 Ref Temp 30 Image Reverse 30 Clear Screen 30 L S Auto Manual Mode 30 5 2 4 Setup 31 System Setup 31 Language 32 Auto Rectify 32 Auto Save 32 Video 32 Transparence...

Page 6: ...Series Infrared Camera the new standard in Infrared imaging industry Typical Application Power Plant Monitor and diagnose the condition of electrical wire and equipment detect power leak and prevent s...

Page 7: ...comes with the following standard items and accessories Item Quantity Infrared Camera 1 Li Ion Battery 2 Battery Charger 1 USB Cable 1 Video Cable 1 User Manual 1 IR Analysis Software CD 1 Suitcase 1...

Page 8: ...indicated direction user can easily insert and remove battery Battery Insertion Battery Removal Device comes with two sets of Li Ion battery and one battery charger It is strongly recommended to opera...

Page 9: ...rging 1 The battery can also be charged by using an adapter Normally it takes 5 hours to charge one battery in this mode 2 3 Attention for Using Battery Charger 1 Battery Charging can only be conducte...

Page 10: ...ress this button to turn on or off the device 2 Power LED Light When device is powered on the Power LED Light will be on 3 4 5 6 Direction Buttons Up Down Left and Right 4 direction buttons have diffe...

Page 11: ...elect Color Palette or temperature measurement limit Press to change and has no effects 7 OK Menu Confirm Button This button has different functions under different conditions In real time Infrared vi...

Page 12: ...ideo Output CVBS standard video output 11 Audio Output Audio output playbacks recorded voice annotation 12 USB 2 0 Interface USB2 0 interface transfers data between device and PC 13 External DC In Ext...

Page 13: ...15 Sound Alarm Buzzer Signal sound alarm when reaches temperature limit 4 Quick Start Reference 4 1 Infrared Image 1 Insert Li Ion battery correctly 2 Long press Power button until LED light is on an...

Page 14: ...etween normal and 2X zoom Upper left LCD corner displays 2 when in 2X zoom 5 When measure result is outside temperature range screen display changes to indicate either below or above temperature range...

Page 15: ...folder 4 The icon indicates voice annotation attached to current thermal image Press button to playback 5 Long press OK button to exit 4 5 Replace Lens 1 Screw off the lens on device replace it with a...

Page 16: ...d to format device periodically 5 Operation Menu 5 1 Display Summary All items can be selected by short pressing the Hotkey button Note Long press Hotkey button will turn on off laser sight The select...

Page 17: ...respectively 8 Line measure the temperature value in the crossing of measure line and cursor line 9 Area measure measure points within the area maximum minimum or average temperature is optional 10 Te...

Page 18: ...r main menu Note if press OK button too long instead of enter main menu triggers manual rectify 13 Main Menu Using and button to select menu item and selected item is highlighted with white background...

Page 19: ...5 2 1 File Using File menu to save playback delete thermal image and voice annotation File Sub menu 14...

Page 20: ...this day is saved in this folder Thermal image file name is Phhmmss and hhmmss is hour minute second according to system time For example P080502 in folder M090102 means the thermal image taken at 08...

Page 21: ...dicates voice annotation data with current thermal image Long press button to enter Voice Annotation menu If voice annotation already exists press Record will record new voice annotation and erase pre...

Page 22: ...current thermal image Freeze image first before saving Format Format the internal FLASH memory Press OK to confirm or cancel to exit Format will erase all saved thermal images It is recommended to tr...

Page 23: ...Measure Sub menu Spot Measure Press or button to select or deselect Selected spot is check marked Up to 4 spots can be selected at the same time 18 Spot Target Selection...

Page 24: ...an be selected Spot Measure Attribute Press Hotkey button until spot marker is flashing in yellow and then use buttons to move spot location to different directions Press OK button to enter Attribute...

Page 25: ...l Line Measure Horizontal Line Measure Horizontal line is temperature sampling line and upper right LCD corner displays temperature measurement reading on vertical cursor line intersection After using...

Page 26: ...Horizontal Line Measure Attribute Vertical Line Measure Vertical Line Measure 21...

Page 27: ...measure press and button to adjust sampling line position and press and button to adjust cursor line position Press OK button to enter Attribute Menu After 2 seconds with no operation system will exi...

Page 28: ...Target Selection 23 Area Rect Measure Measure result on upper right LCD corner is the temperature measurement result within the corresponding rectangle There are 3 measure types max min and average te...

Page 29: ...re Attribute Emissivity Refer to Appendix Emissivity of raw materials Set Reference Set current area as reference If selected all measure result will be relative value to this temperature Measure Type...

Page 30: ...be omitted if target subject is close to device less than 10m Otherwise set Distance value accordingly to get more accurate temperature reading Press or once to change Distance 0 1m Long press or wil...

Page 31: ...e 0 01 Long press or will change ratio value in 0 1 intervals Adjust Temp Under certain condition it is necessary to adjust temperature reading by a pre define value Normally this option should be lef...

Page 32: ...Image Sub menu Image Setup Image Setup Sub menu 27...

Page 33: ...l Default setting is 37 0 O C Alarm Color Alarm Color can select from Auto Black White Red Orange Yellow Green Blue Gray and Purple Default setting is Auto which is no color alarm Isotherm Color When...

Page 34: ...lear battery condition temperature unit temperature limit and color palette Press or to turn on off this option Analysis Setup 29 Analysis Setup Sub menu Temp Range Select Temperature range base on me...

Page 35: ...o correct environmental temperature Press or once to change Ambient Temp 0 1O C Long press or will change Ambient Temp in 1O C interval Reference Set reference spot or area to display measure results...

Page 36: ...are 4 items in Setup menu System Setup Time Date Factory Default and Information Setup Sub menu System Setup System Setup includes Language Auto Rectify Auto Save Video Transparence Display Device Scr...

Page 37: ...ext auto rectify Set value between 1 and 3000 seconds Value 0 means disabling auto rectify feature Auto Save Set the number of seconds to perform next auto save Set value between 5 to 3600 seconds Val...

Page 38: ...power Select between 5min 10min 30min and None Power Save Set the number of minutes without operation to trigger power off completely Select between 10min 20min 30min and None Time Date Set system dat...

Page 39: ...mes known higher demands are being set on buildings The features of our IR camera make it possible to detect slight temperature difference and to analyze indoor humidity and leakage Hereinafter are im...

Page 40: ...The effect drawing of indoor water leakage The effect drawing of indoor corner air leakage 35...

Page 41: ...The effect drawing of outdoor corner air leakage 36...

Page 42: ...easure Mode 4 spots 3 areas available under real time mode max min and average temp line measure isothermal display temp difference measure and temp alarm sound color Color Palette 12 Colors selectabl...

Page 43: ...ne Laser Director Class 2 1mW 635nm Red Battery Type Rechargeable Li Ion Battery BatteryOperating Time 3 Hours Under normal temperature Charging type Intelligent charger Power Save Included Power Supp...

Page 44: ...powered on No battery or batteries are not installed correctly Install battery correctly Battery power is used up Change battery or recharge Save power mode power on after 5 seconds Device power off a...

Page 45: ...00 0 64 Cast Iron inoxidized 100 0 21 Rough 25 0 94 Wrought Iron Polished 38 0 28 Nickel Oxidized 200 0 37 Stainless Steel Oxidized 60 0 85 Steel 800 Oxidized 200 0 79 Brick 20 0 93 Concrete 20 0 92 G...

Page 46: ...Uncooled Focal Plane Infrared Cameras IRSee Report Software User Manual...

Page 47: ......

Page 48: ...3 Software Installation 1 4 Uninstall Software 3 5 Start Software 3 Function Description 4 1 Image Import and Export 4 1 1 Image Import 4 1 2 Image Export 5 2 Modules 5 2 1 Ribbon 6 2 2 Measuring Temp...

Page 49: ...to edit this manual without further notice 2 Quality Assurance The quality administration system of this product during the process of R D and production has been approved in accordance with ISO9001 s...

Page 50: ...or or faster 1Gbytes or more system memory 20G or bigger hard disk 1440 900 or higher resolution screen 2 2 Operating System IRSee Software is compatible with Microsoft Windows 2000 XP Vista Windows 7...

Page 51: ...tep B Click the Next button to access the software installation Step C Click the Next button continuously until the software installation is completed The system will enter the decoder installation au...

Page 52: ...ete button if want to reinstall the software 5 Starting up Software The following icon appears on Windows desktop after installing IRSee software Double click the icon and startup IRSee interface Open...

Page 53: ...the IRSee will be in English version if the operating system is beyond mentioned languages in PC Function Description 1 Image Import and Export 1 1 Image Import Method 1 Click the software icon on upp...

Page 54: ...As button to pop up a file selection dialog box Select a file path and save the image in the current active window Method 3 Click the software icon on the top left corner Click the button Save current...

Page 55: ...current image button to pop up a file selection dialog box Set select the file path name where the file is saved Save the image in the current active window Method 2 Click the File and select the Save...

Page 56: ...option to show the dew point temperature 2 1 2 6 Cancel Changes Click the Return to default settings button to recover the emissivity humidity ambient temperature or distance to its original state 2...

Page 57: ...the Report Edit is mainly used for editing a report for further analysis Click the Report Wizard to select the type of exported report as needed Click Next to select an image or multiple images Fill i...

Page 58: ...9 After necessary information completed you can click the save button to save the report as needed All reports have the same format of HX and repots can be edited again in IRSee software...

Page 59: ...10...

Page 60: ...If a report is to be closed the system will prompt whether to save the report or not Click the OK button Input and select the saving path and file name and then click the Save button Click the report...

Page 61: ...1 Connection Click the Ribbon Settings USB Direct Trans Connect a device set to USB Direct Trans mode for the device Click the device iron on PC software interface Open the device Play 2 1 6 2 Video...

Page 62: ...ge into the Picture folder under the installation directory and name it by a time format 2 1 7 Panel It is mainly used for showing hiding each area a user can adjust the size and position of each disp...

Page 63: ...ects and 10 elliptical objects simultaneously 2 2 1 Select Measured Objects The prior sequence of object selection is point line and area When two or more objects are simultaneously selected the syste...

Page 64: ...to a point to be moved When the mouse status changes to left click to select the point Move the mouse Delete a point Select a measurement point to be deleted Click the button to delete selected Measu...

Page 65: ...zed Left hold and drag the mouse to the horizontal coordinates of terminal point of the line Move and change a line Move Move the mouse to the position of a line to be moved When the state of mouse be...

Page 66: ...ctangle in the thermal image to be analyzed Drag the mouse to create a rectangular analysis area Move and Drag a Rectangle Move Move the mouse into the rectangle target area When the state of mouse be...

Page 67: ...vertexes is equal to or more than 50 the system can stop adding automatically Move and Drag a Polygon Move Move the mouse into the polygon to be analyzed When the state of mouse becomes click to selec...

Page 68: ...tate of mouse becomes click to select it Move the mouse Zoom in out Move the mouse into the ellipse to be modified When the state of mouse becomes click to select it Move the mouse to the eight vertex...

Page 69: ...d only for visible image Click the button to switch between the PIP and infrared modes 2 2 8 Export Temperature Data Click the button to export all the points temperature in the whole thermal image to...

Page 70: ...able to click the button to switch 2 3 3 Enable Disenable Grid If the grid is enabled it is available to draw grid dashed lines on the histogram background if disenabled it s unavailable to draw it is...

Page 71: ...e Reset button to reload the default state to the histogram 2 4 Line Profile Measurement Area 2 4 1 Show hide grid lines Click the Grid button to switch the grid display and hide mode 2 4 2 Set the ba...

Page 72: ...t the maximum or minimum temperature and isothermal upper and lower limits any out of range temperature can not be supported If the dew point is selected the corresponding color code of below the dew...

Page 73: ...k to select Drag the mouse to the required temperature value position Method 2 Click the scroll bar on the arrow button to adjust upper and lower limits each step is 0 1 2 5 4 Select a dew point When...

Page 74: ...ct Select customize a color Click the OK button to conform the color of measured object 2 6 2 Add remarks for measured object Select a measured object in the label list Add Remarks in the Remarks edit...

Page 75: ...2 7 Visible Light 2 7 1 Open an Image Click the Open button to pop up the file selection dialog box Select a file to be added from the dialog box 2 7 2 Save an image Click the Save button to pop up t...

Page 76: ...utton to delete the currently added visible image 2 7 4 Flip an image Click the or button to flip an image clockwise or counterclockwise 2 7 5 PIP This feature is available for any image that with vis...

Page 77: ...s between infrared image and visible image Set infrared display range Drag the right two progress bars to adjust the infrared display range of interval or above upper or below lower limit Click the OK...