ACCESS TO THE DATALOGGER THROUGH THE CONSOLE
PORT (RS232)
The datalogger has an
RS232 port for maintenance and supervision. To use it, you must connect it to
the RS232 of a PC, either directly or via an RS232 to USB converter.
To interact with the datalogger via console, use a terminal application configured as follows:
▪
11500 bps
▪
No parity
▪
8 data bit
▪
1 stop bit
The datalogger is constantly sending operating information through the
RS232 console port. Likewise,
it can perform some special maintenance functions, such as:
Pressing the 'm' key, the device will ask for a password. Enter "sennet" and you will access the options
menu. There, it is possible to modify the basic settings, such as, changing the network settings.
▪
By pressing the 'v' key you will get information on the version of datalogger and application.
▪
Pressing 'i' will get information on the GPRS connection.
▪
Pressing 's' will force an interrogation to the configured devices.
When the datalogger is connected via USB, the external power must be also connected to be fully
functional.