Satel GSM LT-1 User Manual Download Page 8

 

User Manual 

GSM LT-1 

the computer by means of the DLOAD10 program will still be possible). If this is the case, 
turn the module power off and on, so that the module can re-enter the programming mode. 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Figure 3.

 

Entering the SIM card into its socket. 

 
The module power supply should have a sufficient current capacity. The recommended 
power supply unit (e.g. APS-15; APS-30 manufactured by SATEL) should be equipped with 
its own battery. 
It is suggested that the power supply be located within 3 m from the module. 
If the supply voltage is lower than 9.8 V, restart of the module will follow. Therefore, be 
careful that the module supply voltage never drops during operation below 9.8 V at the 
maximum current consumption. 

6. O

PERATION OF THE MODULE WITH ALARM CONTROL PANEL AND STATIONARY 

TELEPHONE

 

As shown in Figure 1, the module is to be directly connected to the control panel’s public 
telephone line terminals. 
It maintains impedance and voltage across the R-1 and T-1 terminals as necessary for 
correct operation of the telephone set. The terminals can be automatically deenergized in 
case of a loss of communication with the base station (which is accompanied by operation of 
the FLT trouble indicator – see: programming function No. 17). 
When the control panel goes „off-hook”, or when a user lifts the handset of a telephone 
connected to the terminals T-1 and R-1, the module will generate the continuous dialing tone 
and receive the tone or pulse dialing signals (similarly as the telephone exchange). 
The telephone number can include digits and special characters: # * +. The phone number 

should be dialed just like from a cellular phone, as required by the operator of the network 
into which the telephone is logged. It is recommended that the number begin with the „+” 
character and country code prefix (48 for Poland). Sometimes you can dial just the mobile 
phone number, or the area code and stationary telephone number. 
Examples: 
[*][0][4][8][5][0][1][1][2][3][4][5][6] –  connection 

to 

mobile phone (with prefix „+48”) 

[5][0][1][1][2][3][4][5][6] – 

connection 

to 

mobile phone (number without prefix) 

[5][8] [1][2][3][4][5][6][7] 

–  connection  to stationary telephone, (in this example, 

58 is location area code) 

1. slide the card 

carrier up 

3. press the carrier to

the plate and slide
the carrier down to
fix it in position 

2. turn the carrier 

aside and slide 
the card into the 
guides 

SIM card 

Summary of Contents for GSM LT-1

Page 1: ...COMMUNICATION MODULE GSM LT 1 USER MANUAL Firmware version 1 12 gsmLT 1_en 02 11...

Page 2: ...da sk POLAND tel 48 58 320 94 00 fax 48 58 320 94 01 Product description Communications module used to simulate PSTN line over GSM network allowing for alarm transmission in case of a failure or lack...

Page 3: ...TH MONITORING STATION 7 8 SENDING SMS MESSAGES 8 8 1 PROCEDURE FOR CONVERTING PAGER MESSAGES INTO SMS MESSAGES 8 8 2 SENDING SMS MESSAGES FROM A STATIONARY TELEPHONE SET 9 9 TEST TRANSMISSION 9 9 1 TE...

Page 4: ...nitoring of the sites possible with the use of SMS messages Functioning as an external modem for the CA 64 and INTEGRA alarm control panel support of DLOAD64 GUARD64 DLOADX and GUARDX programs Operati...

Page 5: ...3 DESCRIPTION OF THE MODULE MODULE TERMINALS 12V power supply input 12 V DC 15 GND ground 0 V FLT alarm output GSM telephone failure or insufficient range OC 50 mA R 1 T 1 extension telephone line co...

Page 6: ...g cycle of these LEDs is 4 seconds repeated after a 1 second pause STAT indicates the module status by a corresponding number of flashes with specified duration Shown symbolically below are single cyc...

Page 7: ...ng the PUK code is possible after putting the SIM card into an ordinary cellular telephone 5 INSTALLATION It should be borne in mind during installation that the GSM LT 1 module must not be located in...

Page 8: ...cally deenergized in case of a loss of communication with the base station which is accompanied by operation of the FLT trouble indicator see programming function No 17 When the control panel goes off...

Page 9: ...phone number of the module SIM card The incoming calls are directed to the extension line terminals R 1 and T 1 which generates the ringing tone in much the same way as with operation of the cable tel...

Page 10: ...rm control panel is off hook and after dialing the number the module checks the first four digits of that number If these digits agree with the programmed Pager tel No in the module the module receive...

Page 11: ...eft hand letter on the given key The right hand letter is accessible by pressing the given key and In order to reach the space press the 0 key To reach the dash press 0 the point press 1 In order to c...

Page 12: ...acknowledgement of CLIP transmission the module will finish dialing the given telephone number The module will call in turn each of the programmed numbers starting from the telephone no 1 If the modul...

Page 13: ...elephone will be ready for reception of a next text message 10 MODULE PROGRAMMING For the module to operate properly corresponding parameters must be programmed The programming is possible by means of...

Page 14: ...figure 7 Figure 7 2 Enter the options of module communication settings by clicking on the icon or through the Communication Configuration menu and select the port through which the computer connects...

Page 15: ...GSM LT 1 SATEL 13 Figure 8 Note Never carry out functional test of the module with cable connected to RS port Figure 9...

Page 16: ...e signals it generates in the handset e g the line busy signal can be heard if there is no SIM card inserted During the process of programming the module is communicating with the user by means of bee...

Page 17: ...nnection with the INTEGRA control panel and the access from DLOADX program is blocked the module will send a SMS message stating that Remote access from DloadX program is not granted to the number pre...

Page 18: ...rogrammed SMS center number is a full international number 0 no for local networks 1 yes recommended 1 1 Fax Modem Option indicating whether the user permits a modem transmission to be carried out by...

Page 19: ...e is unblocked the PIN code currently programmed in the module settings will be loaded into the SIM memory Note After entering the PUK code the SIM card will get unlocked and its PIN code will be chan...

Page 20: ...as for telephone no 1 2 4 telephone number 4 for the test transmission The same settings as for telephone no 1 2 5 test transmission period 6 digits ddhhmm As distinct from function 19 this function e...

Page 21: ...send test transmission to telephone no 1 You can program from 1 to 15 attempts 3 3 number of attempts to send test transmission to telephone no 2 You can program from 1 to 15 attempts 3 4 number of at...

Page 22: ...dule if not used will restart the phone To use the module means to answer a call when calling from the module receive the ring signal in the module confirm sending SMS message from the module receive...

Page 23: ...IMPORTANT PIN PUK Telephone No...

Page 24: ...SATEL sp z o o ul Schuberta 79 80 172 Gdansk POLAND tel 48 58 320 94 00 info satel pl www satel eu...

Reviews: