User Manual
GSM LT-1
18
2 – test transmission period
5 h 57 min,
3 – test transmission period
11 h 56 min,
4 – test transmission period
23 h 55 min,
5 – test transmission period
2 d 23 h 53 min,
6 – test transmission period
6 d 23 h 30 min.
If the function is called by entering
[1][9][*][*][?][?][#]
, the second "?” character will
determine whether the test function is to be random or not:
0 – no,
1 – yes.
By default, the random transmission is disabled.
[2][0][*][*][?][#]
–
test transmission priority
. This option determines whether the test
transmission will override the call being just carried out by the module. If yes, the current
connection will be terminated whenever there is a need for the test transmission. If no, the
test transmission will be carried out on completion of the call by the control panel/user:
0 – no,
1 – yes.
[2][1][*][*][?...][#]
–
telephone number 1 for the test
transmission
. The number of digits
must be within the range of 1...16. The number should be programmed with „+” at the
beginning, followed by the country code. The [2][1][*][*][#] sequence will erase the
previously saved telephone number.
[2][2][*][*][?...][#]
–
telephone number 2 for the test
transmission
. The same settings as
for telephone no. 1.
[2][3][*][*][?...][#]
–
telephone number 3 for the test
transmission
. The same settings as
for telephone no. 1.
[2][4][*][*][?...][#]
–
telephone number 4 for the test
transmission
. The same settings as
for telephone no. 1.
[2][5][*][*][?][?][?][?][?][?][#]
–
test
transmission period
(6 digits: ddhhmm). As distinct
from function 19, this function enables any transmission period to be entered.
The programmed digits have the following meaning:
dd – number of days (max. 31),
hh – number of hours (max. 23),
mm – number of minutes (max. 59).
If the function is called by entering
[2][5][*][*][?][?][?][?][?][?][?][#]
, the seventh "?”
character will determine whether the second test transmission is to be random or not:
0 – no,
1 – yes.
By default, the random transmission is disabled. Programming zeros only will reset the test
transmission.
[2][6][*][*][?...][#]
–
telephone number to confirm SMS control
. The number to which the
module will send an SMS to inform about the current settings, provided that the user has
changed the settings by means of an SMS. The telephone number must be preceded by
the „+” character and country code, corresponding to the currently used GSM network.
The [2][6][*][*][#] sequence will erase the previously saved telephone number.
[2][7][*][*][?][?][?][?][?][?][#]
–
SMS
password
(6 characters) makes it possible to remotely
change the
test transmission period
. Sending to the module an SMS with the
[?][?][?][?][?][?]=P sequence, where P is a parameter corresponding to the description
contained in function 19, will save the new parameter, programmed with function 19, in the
module memory. Using the DTMF signals, you can program passwords composed from