User Manual
GSM LT-1
12
For installation of the program run the
setup.exe
program from a disc delivered with the
module.
Having installed the program, start it. Access to the program is protected with an
access
code.
After installation of the program, the access code is:
1234
and can be changed in any
string of 16 alphanumeric characters. As long as the code has its factory setting, pressing the
„ENTER” key (without entering any code) will start the program with the default access code
(1234).
In order to establish communication between the DLOAD10 program and the module, you
should follow the procedure below:
1. Open the window with module data by selecting
File
Æ
New device
Æ
GSM4/LT module
in the program menu (see: figure 7).
Figure 7.
2. Enter the options of module communication settings by clicking on the
icon
(or through the
Communication
Æ
Configuration
menu) and select the port through
which the computer connects with the module RS-232 port (see: figure 8).
3. Read out data from the module by clicking on the
icon.
4. Program
the
module. Figure 9 shows the window for programming the module settings.
The parameter values in the drawing are just an example. The data related to test
transmission and SMS control, as well as the PIN code, are not programmed by default.
Particular parameters are described in Section „Module Programming”. The line in the
upper part of the window shows the current status of the module as well as the antenna
signal level.
5. Save new data in the module by clicking on the
icon.
6. If necessary, the programmed data can be saved as a file on the computer disk.
7. Disconnect the cable used for programming.