SATEL AOCD-260
7
5 Specifications
Operating frequency band ...................................................................868.0 MHz ÷ 868.6 MHz
Radio communication range (in open area)
ABAX 2
ACU-220 .............................................................................................. up to 2000 m
ACU-280 .............................................................................................. up to 1600 m
ABAX.............................................................................................................. up to 500 m
Battery ................................................................................................................... CR123A 3 V
Battery life expectancy.......................................................................................... up to 2 years
Temperature measurement range .......................................................................-40°C...+55°C
Temperature measurement accuracy ................................................................................ ±1°C
Standby current consumption ...........................................................................................70 µA
Maximum current consumption........................................................................................26 mA
Microwave frequency.............................................................................................. 24.125 GHz
Detectable speed...................................................................................................... 0.3...3 m/s
Warm-up period .................................................................................................................. 45 s
Recommended installation height..................................................................................... 2.4 m
Coverage area ................................................................................................. 10 m x 0.6 m, 6°
Complied with standards..................................................EN50131-1, EN50130-4, EN50130-5
Security grade according to EN50131-2-4 (detector mounted directly to the wall) ....... Grade 2
Environmental class according to EN50130-5 ...................................................................... IIIa
Operating temperature range...............................................................................-40°C...+55°C
Maximum humidity.......................................................................................................... 93±3%
IP code................................................................................................................................IP54
Dimensions ....................................................................................................44 x 105 x 40 mm
Weight............................................................................................................................... 118 g