Satel AOCD-260 Manual Download Page 3

The AOCD-260 detector can detect motion at the moment of crossing the perimeter of 
protected area. It can be a component of perimeter protection. It is designed for operation 
within the ABAX 2 / ABAX two-way wireless system. This manual applies to the detector with 
firmware version 1.00, which is supported by: 

 ABAX 

2: 

– ACU-220 

ACU-280 controller, 

–  ARU-200 repeater.  

 ABAX: 

–  ACU-120 / ACU-270 controller (firmware version 5.04 or newer), 
–  ARU-100 repeater (firmware version 2.02 or newer), 
–  INTEGRA 128-WRL control panel (firmware version 1.19 or newer and firmware 

version of processor used to operate ABAX system 3.10 or newer). 

1  Features 

  Passive infrared (PIR) sensor and microwave sensor. 

 Adjustable 

detection 

sensitivity of both sensors. 

  Digital motion detection algorithm for both sensors. 

 Digital 

temperature compensation. 

  Encrypted two-way radio communication in the 868 MHz frequency band (AES standard 

for the ABAX 2 system). 

  Transmission channel diversity – 4 channels for automatic selection of the one that will 

enable transmission without interference with other signals in the 868 MHz frequency 
band (ABAX 2 system only). 

  Remote update of detector firmware (ABAX 2 system only). 

 Remote 

configuration. 

  Built-in temperature sensor (temperature measurement range from -40°C to +55°C). 

  Tricolor LED indicator. 

  Supervision of motion detection system. 

  “ECO” option for longer battery life (ABAX 2 system only). 

  Battery status control. 

  Tamper protection against enclosure opening and removal from mounting surface. 

  Weatherproof enclosure featuring a very high mechanical strength. 

  Angle-type mounting bracket included. 

2  Description 

Radio communication 

The detector connects to the controller / control panel at regular time intervals to provide 
information about its state (periodical communication). Additional communication may take 
place as a result of alarm (see “Operating modes”). 

Summary of Contents for AOCD-260

Page 1: ...AOCD 260 Wireless outdoor dual technology curtain detector Firmware version 1 00 aocd 260_en 02 19 SATEL sp z o o ul Budowlanych 66 80 298 Gda sk POLAND tel 48 58 320 94 00 www satel eu...

Page 2: ...improve the quality of its products which may result in changes in their technical specifications and software Current information about the changes being introduced is available on our website Pleas...

Page 3: ...ay radio communication in the 868 MHz frequency band AES standard for the ABAX 2 system Transmission channel diversity 4 channels for automatic selection of the one that will enable transmission witho...

Page 4: ...you want to prolong the battery life you can enable in the detector the ECO option When the ECO option is enabled the periodical communication takes place every 3 minutes Thus the battery life can be...

Page 5: ...element pyrosensor 3 Selecting a mounting location Install the detector at the recommended height Fig 4 I Install the detector at a roofed location Fig 2 or under a protective roof Fig 3 where streams...

Page 6: ...the battery The manufacturer is not liable for the consequences of incorrect installation of the battery The used batteries must not be discarded but should be disposed of in accordance with the exist...

Page 7: ...ut the detector there 6 Remove the front cover Fig 5 7 Push the fastening catches outward and remove the electronics board Fig 6 8 Make screw holes in the enclosure base To ensure tightness of the enc...

Page 8: ...AX 2 ABAX controller manual the INTEGRA 128 WRL control panel manual 13 Start the test mode see the ABAX 2 ABAX controller manual the INTEGRA 128 WRL control panel manual 14 Check whether moving aroun...

Page 9: ...C Standby current consumption 70 A Maximum current consumption 26 mA Microwave frequency 24 125 GHz Detectable speed 0 3 3 m s Warm up period 45 s Recommended installation height 2 4 m Coverage area 1...