Satel AOCD-260 Manual Download Page 8

6 AOCD-260 

SATEL 

 

12. Configure the detector settings (sensitivity of PIR sensor, sensitivity of microwave sensor, 

etc. – see the ABAX 2 / ABAX controller manual / the INTEGRA 128-WRL control panel 
manual). 

13. Start the test mode (see the ABAX 2 / ABAX controller manual / the INTEGRA 128-WRL 

control panel manual). 

14. Check whether moving around within the detector coverage area will get the LED to come 

on. Fig. 10 shows the maximum coverage area. 

15. End the test mode. 

 

 

Summary of Contents for AOCD-260

Page 1: ...AOCD 260 Wireless outdoor dual technology curtain detector Firmware version 1 00 aocd 260_en 02 19 SATEL sp z o o ul Budowlanych 66 80 298 Gda sk POLAND tel 48 58 320 94 00 www satel eu...

Page 2: ...improve the quality of its products which may result in changes in their technical specifications and software Current information about the changes being introduced is available on our website Pleas...

Page 3: ...ay radio communication in the 868 MHz frequency band AES standard for the ABAX 2 system Transmission channel diversity 4 channels for automatic selection of the one that will enable transmission witho...

Page 4: ...you want to prolong the battery life you can enable in the detector the ECO option When the ECO option is enabled the periodical communication takes place every 3 minutes Thus the battery life can be...

Page 5: ...element pyrosensor 3 Selecting a mounting location Install the detector at the recommended height Fig 4 I Install the detector at a roofed location Fig 2 or under a protective roof Fig 3 where streams...

Page 6: ...the battery The manufacturer is not liable for the consequences of incorrect installation of the battery The used batteries must not be discarded but should be disposed of in accordance with the exist...

Page 7: ...ut the detector there 6 Remove the front cover Fig 5 7 Push the fastening catches outward and remove the electronics board Fig 6 8 Make screw holes in the enclosure base To ensure tightness of the enc...

Page 8: ...AX 2 ABAX controller manual the INTEGRA 128 WRL control panel manual 13 Start the test mode see the ABAX 2 ABAX controller manual the INTEGRA 128 WRL control panel manual 14 Check whether moving aroun...

Page 9: ...C Standby current consumption 70 A Maximum current consumption 26 mA Microwave frequency 24 125 GHz Detectable speed 0 3 3 m s Warm up period 45 s Recommended installation height 2 4 m Coverage area 1...