SATEL AOCD-260
5
with serial number which shall be entered when registering the detector in the system can
be found on the electronics board.
In the INTEGRA / VERSA alarm system, the detector is identified as AOCD-250.
Simultaneous operation of the detector by the ABAX 2 and ABAX controller /
INTEGRA 128-WRL alarm control panel is not possible.
3. Replace the cover.
4. Put the detector at the place of its future installation.
5. Check the level of signal received from the detector by the ABAX 2 / ABAX controller or
the INTEGRA 128-WRL control panel. If the signal level is lower than 40%, select another
place for installation. Sometimes, it is sufficient to shift the device ten or twenty
centimeters to obtain a considerable improvement in the signal quality.
The ARF-200 tester makes it possible to check the radio signal strength at the place of
future installation without having to put the detector there.
6. Remove the front cover (Fig. 5).
7. Push the fastening catches outward and remove the electronics board (Fig. 6).
8. Make screw holes in the enclosure base.
To ensure tightness of the enclosure, make the holes only at places specially intended
for this purpose.
9. Mount the enclosure base directly to the wall (Fig. 7) or to the angle bracket screwed
down to the wall (Fig. 8). The wall plugs (anchors) delivered with the device are intended
for concrete, brick, etc. For other types of surface (drywall, styrofoam), use the
appropriately selected wall plugs.
For the hole designated by letter A on the figures 7 and
8, use the smaller screw. Fig. 9 shows the possible ways of detector installation (the
detector can also be mounted on the adjustable brackets, BRACKET A and BRACKET B,
offered by SATEL).
If the detector is to comply with the EN50131-2-4 requirements for Grade 2, do not
install it on the mounting bracket (if installed on the bracket, the detector will comply
with the standard requirements for Grade 1).
10. Fasten the electronics board in the enclosure.
11. Replace the cover.