– enter the ARU-100 repeater number in the list of wireless devices, if the device is to
communicate to the controller via the repeater (the ARU-100 repeater takes up two
positions on the list of devices – enter the number of the first of them).
Configuration
Described below is how the additional parameters and options should be programmed in the
“Configuration” column.
AGD-100
– enter a digit from the 1 to 3 range to set the sensitivity (1 – low , 2 – medium,
3 - high).
AMD-100
/
AMD-101
– enter the digit 0 (bottom reed switch) or 1 (side reed switch) to
determine which of the two reed switches is to be active.
AMD-102
– for the magnetic contact, enter the digit 0 (bottom reed switch) or 1 (side reed
switch) to determine which of the two reed switches is to be active. For the roller shutter
input, enter 2 digits:
1
st
digit – number of pulses: from 1 to 8.
2
nd
digit – pulse validity: 0 (30 seconds), 1 (120 seconds), 2 (240 seconds) or 3 (unlimited
duration).
AOCD-250
– enter 2 digits:
1
st
digit – sensitivity of PIR sensor: from 1 to 4 (1 – minimum; 4 – maximum).
2
nd
digit – sensitivity of microwave sensor: from 1 to 8 (1 – minimum; 8 – maximum).
AOD-200
– for the first position taken by the detector, enter 3 digits:
1
st
digit – sensitivity of PIR sensor: from 1 to 4 (1 – minimum; 4 – maximum).
2
nd
digit – sensitivity of microwave sensor: from 1 to 8 (1 – minimum; 8 – maximum).
3
rd
digit – sensitivity of dusk sensor: from 1 to 4 (1 – minimum; 4 – maximum).
APMD-150
– enter 3 digits:
1
st
digit – sensitivity of PIR sensor: from 1 to 4 (1 – minimum; 4 – maximum).
2
nd
digit – sensitivity of microwave sensor: from 1 to 8 (1 – minimum; 8 – maximum).
3
rd
digit – the way of operation in the test mode: 0 (alarm triggered after motion is sensed
by both detectors), 1 (alarm triggered after motion is sensed by infrared detector) or 2
(alarm triggered after motion is sensed by microwave detector).
APD-100
– enter 2 digits:
1
st
digit – sensitivity: 1 (low), 2 (medium) or 3 (high),
2
nd
digit – pet immunity option: 0 (disabled) or 1 (enabled).
ARD-100
– enter a number from the 1 to 16 range to determine sensitivity (1 – minimum;
16 – maximum).
ASD-150
– enter 2 digits:
1
st
digit – option to signal alarm from other ASD-150 detectors: 0 (disabled) or 1 (enabled).
2
nd
digit – option to send out alarm to other ASD-150 detectors: 0 (disabled) or 1
(enabled).
ATD-100
– for each position taken by the detector, enter in turn:
letter H (high temperature threshold) or L (low temperature threshold);
numerical value corresponding to a temperature from the -30°C to +70°C range (with up
to 0.5° accuracy),
numerical value corresponding to a tolerance from the 0.5°C to 10°C range (with up to
0.5° accuracy).