12 ACU-120
SATEL
In case of devices which, in addition to zones, also take up outputs, it is recommended that
you add them to the system first. This will allow you to maintain the continuity of use of not
the zones alone, but the outputs as well. Table 2 shows a situation in which the siren first
output occupies position 8, and the second output – position 9. As a result, 16 outputs have
been reserved for wireless devices in the system, though actually 2 outputs are used (the
eighth output in the first group of 8 outputs and the first output in the second group of 8
outputs).
In some cases, the gaps in the list of zones/outputs cannot be avoided. It applies to situation
when the number of zones/outputs, which is used by the devices, is not a multiple of 8.
Fig. 4. DLOADX
program: the list of wireless devices registered in the controller connected to
INTEGRA / INTEGRA Plus control panel.
For each group of 8 zones /outputs, one address on the expander bus is reserved. The
controller can occupy from 1 to 6 addresses. This must be taken into account at the system
design stage and sufficient number of free addresses must be left for the controller. If, when
new wireless devices have been added to the controller, it turns out that next addresses are
needed, and these are taken up by other devices, successful completion of the expander
identification procedure will be impossible. It will be necessary to change addresses of the
devices connected to the bus.
Adding new wireless devices
DLOADX program
You can add wireless devices in the “Structure” window, “Hardware” tab, after clicking on the
controller name in the list of devices.
1. Click on the “Read” button. The data related to wireless devices will be read from the
controller (these data are not read after clicking on the
button in the main menu).
2. Click on the “New device” button. The “New wireless dev.” window will open.