Step #7 – Inside Escutcheon Wire Connections

Images are shown without gasket. 
If gasket is necessary, refer to Step #5. 
Before the controller is attached  

to the door:

1.  Attach the reader assembly  

ribbon cable into the back   

of the controller assembly  

(side that faces towards  

the door when mounted  

(Fig. 7A). 

2.  Attach the ground wire to  

the bottom of the controller  

assembly (E1, Fig. 7A).

3.  Connect the cable from  

the lock body to the                                                    

bottom of the controller  

assembly (TB1, Fig. 7B).

If 

Hardwiring

 is required,  

go to “Hardwiring Options” 

on page 16.

4.  Place extra wire inside door hole  

and/or outside escutcheon,  

being careful not to pinch wires.

Connectors go on only one way. 
Do not offset connectors, and make  

sure they are completely seated.

Ground 

Wire

Fig.  7A

1

Outside 

Escutcheon

2

Ground 
Wire

Reader 
Cable

Reader 
Ribbon 

Cable

1

Inside 

Escutcheon  

(Back)

3

TB1

Inside of Door

3

2

Lock  

Cable

Red

Black

Red

Black

Green

Green

With  

Deadbolt 

Without 

Deadbolt 

Fig.  7B

Lock Body  

Wire Harness

Lock Body  

Wire Harness

TB1

Ground

Motor  

Connector

Remote Power 

REX Connector

TB1

TB1

3

1

E1

Summary of Contents for Profile Series

Page 1: ...facturing Company an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited Profile Series Dorm Lock Installation Instructions v G1 5 ...

Page 2: ...use harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which th...

Page 3: ...curity performance and durability This product is operated by six 6 AA alkaline batteries Specifications Latch Stainless steel Deadbolt Stainless steel Guardbolt Stainless steel non handed Handed Easily field reversible without disassembling the lock body Case 12 gauge heavy duty wrought steel 3 4 2 Outside lever controlled by any combination of keypad proximity or RF technology Inside lever retra...

Page 4: ...acturing Company is prohibited 11 30 17 Profile Series v G1 5 Mortise Dorm Lock 5 Parts Breakdown 35 2 800 810 WIRE 9473 www sargentlock com A7855B Profile Series v G1 5 05 04 09 A7855 B 11 11 27 28 29 5 4 3 7 2 16 17 15 14 8 9 15 31 21 22 20 20 18 19 25 23 24 26 21 22 26 16 1 17 30 13 13 12 24 33 4 17 30 1 11 5 17 16 20 17 20 11 2 15 14 31 22 21 20 18 19 20 23 24 25 26 8 9 26 21 13 13 24 16 12 22...

Page 5: ...82 0492 Inside Escutcheon Housing Only without Thumb Turn 1 82 0494 Inside Escutcheon Housing Only with Thumb Turn 1 52 2440 100 LK User Key Pad Controller Assembly 1 52 2783 2000 G1 LU User Controller Assembly 1 52 2784 2000 User G1 PA G1 PK Controller Assembly 1 52 2786 2000 User Keypad Prox Controller Assembly with RF Technology G1 TA G1 TP 1 52 2785 2000 User Keypad Controller Assembly with RF...

Page 6: ...rmining the door hand B Prepare Door Prep door according to Instruction Sheet A7457 and appropriate template Manufacturer Door Template 4533 Through bolt Hole Outside Cylinder Hole 76 and 78 Functions Lever Handle Hole Pre drilled and or Tapped Holes 2 places Mortised Pocket Ribbon Cable Hole Controller to Keypad Inside Cylinder Hole Thumb Turn Lever Hole Lever Handle Hole Outside of Door Inside o...

Page 7: ...e the screwdriver 90 to push latchbolt out until back of bolt clears lock case front 3 Rotate latchbolt 180 until the latchbolt drops back into the lock body Note Latch cannot be unscrewed Latchbolt Spade Shaped Slot Fig 2B A Reverse Lock Hand Red surface of locking piece must face the outside locked side of door To rotate locking piece Fig 2A 1 Position lock body with red surface of locking piece...

Page 8: ...1 Drill 2 1 8 x 1 1 4 deep holes in the door if not already present Refer to template for fire stop prep locations 2 Attach with flap up and out using 2 8 x 1 2 self tapping screws for wood and metal doors B Weather Conduit P N 52 2847 Install weather conduit on NON FIRE RATED exterior doors only 1 Carefully insert the weather conduit into the ribbon cable hole on the inside of the door Fig 4B 2 P...

Page 9: ...recting the mounting posts through the door and lock body Fig 6B 3 Make certain the lever spindle is properly engaged in lock 4 On the inside of the door insert spindle into square hole of mortise lock 5 Slide inside adapter and plate assembly over spindle and loosely secure with 2 through bolt screws 8 32 x 5 8 Note For 8276 and 8278 loosely thread cylinder through escutcheon and into the lock bo...

Page 10: ...oor when mounted Fig 7A 2 Attach the ground wire to the bottom of the controller assembly E1 Fig 7A 3 Connect the cable from the lock body to the bottom of the controller assembly TB1 Fig 7B If Hardwiring is required go to Hardwiring Options on page 16 4 Place extra wire inside door hole and or outside escutcheon being careful not to pinch wires Connectors go on only one way Do not offset connecto...

Page 11: ... Lock LH LHR Lock Configuration Installation of Motor Harness and Inside Lever Monitor Switch RH RHR Lock Configuration For RH RHR lock Connect lock s two pin connector with white orange wires to adapter harness as shown in Fig 7D Note To disconnect the two pin connectors press tab and pull connectors apart gently For LH LHR lock Connect lock s two pin connector with blue yellow wires to adapter h...

Page 12: ...r through the spring and rosette collar and screw into lock body rotating the cylinder clockwise Fig 9A Cylinder should be flush with rosette collar Note The 43 cylinder may be used when installing this product with or without a gasket Note SARGENT logo must be horizontal and on the top of the cylinder Fig 9B 2 Secure the cylinder by tightening cylinder clamp screw located above the deadbolt using...

Page 13: ...screws through top and bottom of the escutcheon Fig 11 Thread into outside escutcheon Note For RF Technology versions G1 TU G1 TP G1 TA refer to RF Technology Lock section on page 14 to install through bolt screws 2 Straighten escutcheons and tighten securely being careful to avoid pinching wires 3 Attach inside cover to escutcheon making sure to line up tabs with retaining slots in cover 4 Secure...

Page 14: ... and Remove Batteries A Install Batteries and Keeper 1 Place 6 AA batteries into the compartment being careful to properly align polarity Fig 12A 2 To install battery keeper insert the tabs on the bottom of the keeper into the battery compartment slots and press the keeper tightly against batteries and inserting tabs into bottom slots For RF technology use RF Technology lock information RF Technol...

Page 15: ...addition The antenna board must be carefully moved to access the upper through bolt screw Care should be taken to prevent damage to the antenna retaining tabs during this process Fig 7 1 Press the two tabs away from the antenna board and lift the board off the mounting posts 2 Insert the flat head through bolt and secure the escutcheon in place 3 After tightening the top through bolt replace the a...

Page 16: ...door manufacturer when specified during ordering process 2 Wiring to pigtail harness is per facility wiring requirement ElectroLynx connector terminations and wire colors all match 3 If door does not have an ElectroLynx type door harness cut connectors off product and hard wire or consult factory for appropriate mating harness ElectroLynx As part of their promise to provide innovative fast and eff...

Page 17: ...the battery keeper back under the bottom opening between the controller and escutcheon and attach at the bottom of the controller Note Connectors go on only one way Do not offset connectors and make sure they are completely seated A Fig 1 ElectroLynx Lock Wire Connections Door Position Switch DPS Install the SARGENT 3287 Door Status Switch according to instructions included in the kit Wire the 328...

Page 18: ...d Propped harness and hard wire to non ElectroLynx two conductor door harness b DM requires two conductors c Hard wire door harness to power transfer device d Hard wire door status switch to power transfer device Fig 2 Forced Propped Door Connector J4 Forced Propped Door Option ElectroLynx Wiring System Door Status Switch Wire for switch contact closure when door is opened Typical locations shown ...

Page 19: ...quires two conductors c Hard wire door harness to power transfer device d Hard wire door status switch to power transfer device IMPORTANT 6 AA batteries MUST be removed from controller when using 3267 power supply Ground Tab E3 TB2 Remote Power Unlock Connector TB1 Motor Connector Door Inside Escutcheon Outside Escutcheon A Fig 2 Remote Powering and Remote Unlocking ElectroLynx Wiring System QC4A ...

Page 20: ...s to power transfer device d Hard wire door status switch to power transfer device IMPORTANT 6 AA batteries MUST be removed from controller when using 3267 power supply Ground Tab E3 TB2 Remote Power Unlock Connector TB1 Motor Connector Door Inside Escutcheon Outside Escutcheon A Note Refer to 3267 Power Supply Instruction Sheet A7477 Fig 2 Remote Powering and Remote Unlocking ElectroLynx Wiring S...

Page 21: ...ices with cylinders insert key into cylinder and rotate Check to see if 1 The key retracts the latch Key should rotate freely Key should extend and retract the deadbolt if applicable 2 The inside lever retracts latchbolt Thumbturn should extend and retract the deadbolt if applicable 3 Enter 1234 to unlock outside lever handle and retract latch and deadbolt if provided Note If the lock is prox only...

Page 22: ...ovation and replacement applications The company s customer base includes commercial construction institutional and industrial markets Copyright 2017 Sargent Manufacturing Company an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited ASSA ABLOY is the global leader in door opening solut...

Reviews: