1 Template
Instructions
<<Delete before
use>>
EC
60
0
EC600 Power Control System
Issue 2.3
Page 11 of 20
10
th
August 2017
3.10 AC Current Limiter Operation
The EC600 system features a 230V current monitoring system which allows the mains hook up current
to be displayed on the control panel. The resolution of this reading is 0.5A
. A
current limit setting can
be activated which if reached will switch off the electric elements in the heating system, until such time
as the current drops and the elements will be switched back on. An example of this is if a kettle was to
be operated whilst the heating was on and the current limit was reached then the heater electric
element would be temporarily switched off, when the kettle had boiled then the heater element would
be switched back on automatically.
This feature is particularly useful when abroad on a low current supply. A warning that the limit has
been reached is displayed on the control panel.
Setting the value to OFF will disable this feature.
The Swift Command App can be used to adjust this feature.
3.11 Lighting & Dimming Operation
The system contains up to two dimming channels for groups of lights which can be controlled by the
dimmer button. Some motorhome models also feature an additional furniture mounted dimming
control.
The awning light on a caravan can be controlled by a number of items within the caravan, the local
switch adjacent to the entry door (if fitted), the alarm system lighting button, the control panel awning
light button and the App. Each item can toggle the light on or off.
The awning light on a motorhome can again be controlled by a number of items, the control panel
awning light button, the App and the lock and unlock system (dependant on system setting being set to
do so). Each item can toggle the light on or off.
The Swift Command App can be used to both configure and adjust the lighting and dimming.
3.12 Heating Controls
There are a number of heating systems that can be controlled by the EC600. The system will be
preconfigured by the manufacturer or supplying dealer. The following menu items are only available in
Timer control mode, and 3 examples are shown for the different heating system variants.
Scroll to the Heating Settings and press select to set or adjust the following items:
ALDE 3020
Menu Item
Description
Control
Set to MANUAL to use the controls supplied by the heating
appliance manufacturer
Set to TIMER to control the appliance by the control panel with the
settings below
Set to APP control the appliance by the Swift Command app
The following menu items are only available when in Timer control mode
Electric
Set the electric element to OFF, 1KW, 2KW or 3KW
Gas
Set gas heating ON or OFF
Timer 1
Set the timer 1 event time
This setting adjusts in 15 minute increments
and uses the 24 hour clock
Example 07:30
T1 Heating
Set the timer 1 heating temperature
This setting can be off, or 5 through to 30
degrees C
Example 22 deg C
T1 H/Water
Set the timer 1 hot water temperature
This setting can be OFF, NORML or BOOST
Example Boost
The menu now repeats for timer 2 through to timer 4