33
Diagnostic Messages Cont...
MESSAGE
MEANING
ACTION
SnS
Sensors are out of balance. If this is
If the problem persists, contact
alternating with the temperature it
your dealer or service
may just be a temporary condition.
organization.
If the display shows only this message
(periodically blinking) the spa is shut down.
HFL
A substantial difference between the
Check water level in spa. Refill
temperature sensors was detected.
if necessary. If the water level
This could indicate a flow problem.
is okay, make sure the pumps
have been primed. If problem
persists, contact your dealer or
service organization.
LF
Persistent low flow problems.
Follow action required for
(Displays on the fifth occurrence of
“HFL” message. Heating
the “HFL” message within 24 hours).
capacity of the spa will not
Heater is shut down but other spa
reset automatically, you may
functions continue to run normally.
press any button to reset.
drY
Inadequate water detected in heater.
Check water level in spa. Refill
(Displays on third occurrence of “dr”
if necessary. If the water level
message). Spa is shut down.
is okay make sure the pumps
have been primed. Press any
button to reset.
pr
When your spa is first actuated it
The Priming mode will last for
will go into Priming mode.
up to 4 minutes and then the
spa will begin to heat and
maintain the water
temperature.
sbY
Standby mode has been activated by
Press any button to leave
pressing a button combination on the
Standby mode and return to
user panel.
normal operation.