3

Important Safety Instructions

DANGER

SHOCK HAZARD

•  Keep the electricity to this device 

turned OFF until the clock installation 
is complete. 

•  Do not expose the clock movement to 

water, or install the clock in a location 
where it may be exposed to water.

WARNING

FIRE HAZARD

•  Always follow your national and regional 

electrical codes or ordinances. 

•  The AC power circuit for the device must 

be attached to a circuit breaker that can be 
reset by the user.

PHYSICAL INJURY HAZARD

•  If you are standing on an object while 

installing your device, make sure that the 
object can support your weight, and will 
not sway or move as you stand on it. 

•  Take precautions to avoid injury by 

potential safety hazards near the point 
of installation including (but not limited 
to) heavy machinery, sharp objects, hot 
surfaces, or exposed cables carrying an 
electric current. 

•  Follow all mounting instructions exactly as 

stated in this manual. Failure to do so may 
result in the device falling off the point of 
installation.

•  Packaging materials and mounting items 

include plastic bags and small pieces, 
which pose a suffocation hazard to young 
children.

 

NOTICE

•  Do not install the device outdoors. Damage 

to the device if placed outdoors voids the 

warranty.

•  Do not hang objects from the device or device 

mounting parts. The clocks are not designed 

to support the weight of other objects.

•  After being powered down, the housing may 

be cleaned with a damp cloth or disinfectant. 

Test other cleaning products on a small part 

of the clock housing before attempting to 

use on the rest of the clock. Avoid bleach 

and chemicals known to dissolve plastics.

,

H

|

Summary of Contents for SCB-100-000-1

Page 1: ...er Box SCB 100 000 1 Version Number 1 3 The Sapling Company Inc 1633 Republic Road Huntingdon Valley PA 19006 USA 1 215 322 6063 P 1 215 322 8498 F www sapling inc com Current as of March 30 2018 Inst...

Page 2: ...t 9 10 2 Wire Digital Communication and Wiring Information 11 14 Status Panel 15 Troubleshooting 16 17 Warranty 18 For information on how to install and configure SMA SAM or SBD model clocks please co...

Page 3: ...cautions to avoid injury by potential safety hazards near the point of installation including but not limited to heavy machinery sharp objects hot surfaces or exposed cables carrying an electric curre...

Page 4: ...152 m 16AWG 1 31 mm2 16AWG 1 31 mm2 16AWG 1 31 mm2 16AWG 1 31 mm2 16AW 1 31 mm2 16AWG 1 31 mm2 16AWG 1 31 mm2 500 599 ft 152 183 m 16AWG 1 31 mm2 16AWG 1 31 mm2 16AWG 1 31 mm2 16AWG 1 31 mm2 16AWG 1 3...

Page 5: ...t Clocks 0 138A each Feet Meters 10 15 20 25 30 35 Distance feet meters 0 99 ft 0 30 m 16AWG 1 31 mm2 16AWG 1 31 mm2 16AWG 1 31 mm2 16AWG 1 31 mm2 16AWG 1 31 mm2 14AWG 2 08 mm2 100 199 ft 30 60 m 16AW...

Page 6: ...ll Mount Included in Package 1 Converter Box Description Quantity Picture 2 Mounting kit M SURF MNT KIT 1 1 1 Included in Wiring and Mounting Kit 2a 10 1 5 Sheet Metal Screw 4 A user will also have to...

Page 7: ...oles 1 Use a ruler and a level to mark four points on the wall The screws should have a horizontal separation of 5 inches 12 7cm and a vertical separation of 9 and 7 8 inches 25 1cm Installing a Conve...

Page 8: ...Attach the signal wiring to the input ports and at least one pair of output ports 8 If the Master clock has been connected powered and configured and the converter box is powered and operating normall...

Page 9: ...talling a Converter Box Rack Mount Included in Package 1 Converter Box Description Quantity Picture 2 Rack Mount Flaps 1 2 A user will also have to provide a Phillips head screwdriver a mounting rack...

Page 10: ...and at least one pair of output ports 4 Use the rack screws and nuts to attach the converter box to the rack 5 If the Master clock has been connected powered and configured and the converter box is p...

Page 11: ...lock 24VAC SAM Series Wired Clock 19 White Black White Black Orange Yellow 115VAC or 230VAC 18 Input A Input B A1 B1 C1 A2 B2 C2 Converter Box Converter Box Converter Box Input A Input B 115VAC or 230...

Page 12: ...The Sapling Company Inc 1633 Republic Road Huntingdon Valley PA 19006 USA P 1 215 322 6063 F 1 215 322 8498 www sapling inc com 12 2 Wire Digital Communication Wiring Information...

Page 13: ...The Sapling Company Inc 1633 Republic Road Huntingdon Valley PA 19006 USA P 1 215 322 6063 F 1 215 322 8498 www sapling inc com 13 2 Wire Digital Communication Wiring Information...

Page 14: ...The Sapling Company Inc 1633 Republic Road Huntingdon Valley PA 19006 USA P 1 215 322 6063 F 1 215 322 8498 www sapling inc com 14 2 Wire Digital Communication Wiring Information...

Page 15: ...on and off A black circle alone indicates that the LED in question is off 1 2 3 4 5 6 7 8 1 OUTPUT LED PAIRS The converter box has three Output LED pairs A B and C Each pair of output LEDs acts as an...

Page 16: ...uestion is off If the Output LED nearest to the P in OUTPUT remains on and the Output LED nearest to the O remains off then no data is being received by the converter box If the Master Clock was confi...

Page 17: ...ch If the solid red light reappears check to confirm that the air vent is not blocked and that the converter box has been installed in a room temperature environment If both conditions have been prove...

Page 18: ...by The Sapling Company Inc To Goods which are altered modified or repaired in any place other than a Sapling Company Inc factory or by persons not expressly authorized or approved in writing by The Sa...