3) Plug the power cord into the socket on
the converter box.
1) Use a screwdriver and the #10-32x3/8
Truss Head Phillips Black screws to attach the
converter box rack panels to both sides of the
converter box.
Installing a Converter Box
—
Rack Mount
2) Attach the signal wiring to the input ports
and at least one pair of output ports.
4) Use the rack screws and nuts to attach the
converter box to the rack.
5) If the Master clock has been connected, powered, and configured, and the converter box
is powered and operating normally, the colored LEDs on the front panel should be lit or not lit
depending on their function. See the Status Panel section of this manual for more information.
POWER
INP
UT
A
2-Wire
OUTPUT
A1A2 B1B2 C1C2
INP
UT
B
RS485
Output*
*The RS485 Output extends the RS485 signal to
other converter boxes. It DOES NOT provide 2-wire
power to clocks. Output A goes to Input A on the
next box, and Output B goes to Input B.