24
Diagnostic #4
This diagnostic will test the battery level of the clock.
In order to enter Diagnostic #4 mode, push the Diagnostic Switch four (4) times which is indicated by the LED flashing four times every three
seconds.
The second hand will display the battery level by stopping one of the numbers on the clock’s face.
For example:
•
If the second hand lands on 2, the battery level 2.2V.
•
If the second hand lands on 5, the battery level is 2.5V.
•
If the second hand lands on 9, the battery level is 2.9V.
•
If the second hand lands on 10, the battery level is 3V.
•
If the second hand lands on 11, the battery level is more than 3V.
Diagnostic Testing