15
Setting Camera Performance <CAMERA>
By default, the synchronization adjustment for the camera is performed internally (INT). However, you must make adjustments
in the Line-Lock Setting (L-L) screen, if the monitor screen seems out of sync after switching over among multiple cameras
using AC 24 V. Select a camera as a reference and adjust the others based on the selected one.
Note:
The Line-Lock setting is not available for DC 12 V operation.
1
Set <SYNC> to “L-L” and press the SET button.
R
The “L-L SETTING” screen appears.
2
Adjust synchronization (0 – 524).
• Make adjustments so that the vertical synchronization of the
monitor screen does not move up or down.
3
Select <MENU> – “BACK” and press the SET
button.
R
Returns to the camera performance screen.
• If you want to close the settings screen, set to “END” and press
the SET button.
Adjusting Synchronization Error <SYNC>
·SYNC
L-L
·SYNC
BLC
IRIS
WHITE BALANCE
AGC GAIN
GAMMA
SHUTTER
APERTURE
DAY/NIGHT
PRESET
MENU
L-L y
OFF
SET y
ATW
NORM
0.45
60
HIGH
AUTO y
OFF
BACK
SET
R
Lamp
■
INT
Internally synchronized
• Lamp turned on.
■
L-L (Line-Lock)
Synchronizes the unit with power frequency
• Lamp blinking.
L-L SETTING
<V SYNC PHASE>
· 250
For accessing the main menu, see pages 7 – 8.