BASIC OPERATIONS
Use the following settings and connections to operate this camera with a system controller (sold separately) .
1
Make connections with all equipment turned
off.
2
After referring to “INSTALLATION METHOD”
Step 3, remove the power supply unit and set
the dip switches on the camera’s circuit
board. (See p4)
Terminate setting (System control setting
switches):
Initial setting is ON. When several cameras are
connected together, the last camera in the series
should be set to ON and the other cameras set to
OFF.
(System controller settings):
Set the TERMINATE position (ON/OFF) of the
“ADDRESS/TERMINATE” DIP switches on the back
panel.
Baud rate (System control setting switches):
Initial setting is 19200bps. To set a different baud
rate, change the switches to the appropriate settings.
(System controller settings):
Set the baud rate at the “BAUD RATE SET” item on
the menu screen.
Note: Be sure the controller and the camera are set to the
same baud rate.
Address setting (Address setting switches):
Initial setting is all switches to “0”. The address can
be set from 0 to 127. To set an address, refer to
“ADDRESS SETTING TABLE” and then move the
switches. (See p45)
(System controller settings):
Set the ADDRESS position (1 – 3) of the
“ADDRESS/TERMINATE” dip switches on the back
panel.
3
Install the power supply unit and turn on
power to all equipment.
When the power is turned on, the camera will perform
its startup movements. The camera’s address will flash
on the monitor screen.
4
Operation of the camera with the system
controller
Operation methods are described below. For detailed
information about operation, see the instruction manual
of the system controller.
Type of camera operation with the system
controller
Direct input from “CAMERA” keypad buttons.
This operation makes needed adjustments to the
camera’s basic settings according to photographic
factors such as light compensation and shutter
speed.
The FUNCTION button on the system controller
enables selection a command from 5 types of
call-up commands.
(Call-up commands)
•
ALARM OUT
•
L-L PHASE
•
ZOOM PRESET
•
RESET
•
PRESET MEMORY
Note:
•
Group operation enables setting and operation of groups
1 –- 15. Do not use group 0 (ALL) or category “ALL”.
•
When a magnification power is set for the electronic sensitivity,
it can also be adjusted with the “ELS” button on the system
controller.
•
If SENSE UP and the electronic shutter are both OFF, pressing
the “ELS” button on the system controller will automatically set
electronic sensitivity boosting to “x8”.
CAMERA ADDRESS
001
(Example)
“CAMERA” keypad
camera commands
Numeric keypad
FUNCTION button
English
– 7 –