ALARM SETTING
Alarm output setting (ALARM OUT)
Selects the port for alarm output.
Use the joystick lever (
j
or
l
) to move the cursor to ALARM
OUT, then use the joystick lever (
d
or
c
) to set the alarm
output port.
Available settings:
•
1: Output to alarm 1
•
2: Output to alarm 2
•
OFF: Does not output an alarm
Line output setting (LINE OUT)
Sets ON/OFF condition for alarm output to the communications line.
Use the joystick lever (
j
or
l
) to move the cursor to LINE
OUT, then use the joystick lever (
d
or
c
) to select the alarm
output for the communications line.
Available settings:
•
ON: The alarm signal is output to the communications line.
•
OFF: The alarm signal is not output to the communications line.
Alarm duration setting (DURATION)
Sets the duration of an alarm.
Use the joystick lever (
j
or
l
) to move the cursor to
DURATION, then use the joystick lever (
d
or
c
) to select the
alarm duration.
Available settings: 5S, 10S, 15S, 20S, 30S, 60S, 2M, 3M, 4M, 5M
Note: The alarm duration setting is only applied for an alarm that
matches the set alarm number. Subsequent alarms for the
same number will not be received during the set amount of
time. However, if an alarm input with a different number is
detected, the alarm will be immediately received and from
that point operation will start based on settings selected for
that alarm number.
4
Canceling a settings screen
•
Use the joystick lever (
l
) to select BACK for MENU, then
press the ENTER button. The ALARM screen will reappear.
•
To return to the normal screen, use the joystick lever (
l
c
) to select END for MENU, then press the ENTER button.
B Alarm output setting
1
In the MAIN MENU, select ON for ALARM and press the
ENTER button.
The ALARM screen will appear.
2
Use the joystick lever (
j
or
l
) to move the cursor to
ALARM OUT, then use the joystick lever (
d
or
c
) to
select the external alarm output number. (Ex: 2) Then
press the ENTER button.
The ALARM OUT 2 screen will appear.
3
Use the joystick lever (
d
or
c
) to select POLARITY
between “NO” and “NC”.
Available settings:
•
NO: Normal open (Normally open so closed condition is
detected as input.)
•
NC: Normal closed (Normally closed so open condition is
detected as input.)
4
Canceling a settings screen
•
Use the joystick lever (
l
) to select BACK for MENU, then
press the ENTER button. The ALARM screen will reappear.
•
To return to the normal screen, use the joystick lever (
l
c
) to select END for MENU, then press the ENTER button.
Adjust the alarm input settings for ALARM OUT 2 as needed.
External alarm output time setting
(ALARM TIME)
Use the joystick lever (
j
or
l
) to move the cursor to ALARM
TIME, then use the joystick lever (
d
or
c
) to select the
amount of time for external alarm output.
Available settings: 2S, 5S, 10S, 15S, 20S, 30S, 60S, 2M, 3M,
4M, 5M
ENTER
ALARM
ALARM IN 1 ‚
MOVE MODE OFF
ALARM OUT 2 ‚
ALARM OUT 2
POLARITY NO
ALARM TIME 5S
ALARM OUT 2
POLARITY NO
ALARM TIME 5S
– 42 –
English