– 32 –
SM830035
2
2. Processes and functions
2-4
Outdoor Fan Speed Control
To optimize the performance of air conditioner, the outdoor fan speed is selected
automatically according to the outdoor temperature.
❑
Note that in both Cooling and Heating modes, the fan comes on at first at
high speed (H mode) for 5 seconds. Since outdoor conditions sometimes
make it difficult for the fan to start, this sudden surge of power may be
necessary.
❑
The outdoor fan operates in H mode for 3 minutes after the compressor stops
(excluding defrosting operation period).
❑
Charts below show how the outdoor fan speed changes with the change in
outdoor temperature.
(A)
Cooling
Outdoor unit coil
Outdoor fan
temperature [C2]
motor (FMo)
Not less than 25
°
c
H
Not more than 25
°
c
M
OUTDOOR TEMPERATURE (
°
C)
25
H
M
OUTDOOR TEMPERATURE (
°
C)
14
M
H
Outdoor coil
Outdoor fan
temperature [C2]
motor (FMo)
Not less than 14
°
c
M
Not more than 14
°
c
H
(B)
Heating
Fig. 6
Fig. 7