SM830035
– 80 –
4
4. Service procedures
(6)
Procedures When a Specific Component Does Not Work
1)
Indoor fan does not operate.
No
Yes
Is fan motor capacitor
normal ?
Is there voltage output
of P.C.B. Ass'y for fan
motor ?
• Check resistance of
fan motor winding.
Replace the fan motor.
Replace the capacitor.
Replace the P.C.B. Ass'y
in the indoor unit.