7-2-3. Diagram of Outdoor Unit Installation
CRV243
CRV303
Inspection panel
Fig. 7
Power breaker
Cable fastener
Indoor unit
Ensure 150 mm
of space if a
drain hose is to
be used.
Base(not provided)
(concrete or similar
material)
Fastened with anchor
bolts(not provided)
(M10, 4 locations)
Ground wire
(not provided)
Tubing
panel
Tubing panel
Unit: mm
Over 250
Service space
Over 10
Over 200
Over 500
Ensure 150 mm
of space if a
drain hose is to
be used.
Base(not provided)
(concrete or similar
material)
Fasten with anchor bolts
(not provided)
(3/8" or M10, 4 locations)
Inspection panel
Ground wire
(not provided)
Tubing
panel
Power breaker
Cable fastener
Unit: mm
Indoor unit
Over 10
Over 250
Service space
Over 500
Fig. 7
Using the tubing panel and covers
(1) Place covers over positions that
tubes do not pass trough.
(2) Adjust the tube positions and
attach the tubing panel.
The dimensions indicated by in the figure below
are spaces that are required in order to maintain
performance. Install in a location where the dimensions
indicated by are ensured, and where 2 or more
faces of the unit are unobstructed. In principle,the top
direction should be unobstructed.