9
Indoor Unit
SAP-KRV303GJ
Control PCB
Part No.
Controls
Control circuit fuse
POW-KMRV243GJ
Microprocessor
2.50V 3.15A
Remote Control Unit
RCS-3MVPS4E
Flap Motor and Louver Motor
Type
Model
Rating
Coil resistance (Ambient temp. 20˚C)
Ω
Stepping motor
MP24GA2...2
DC 12V
Each terminal (1-2, 1-3, 1-4, 1-5): 400
*
7%
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Heat Exchanger Coil
Coil
Rows
Fin pitch
mm
Face area
m
2
Aluminum plate fin/Copper tube
2
1.3
0.214
Fan & Fan Motor
Type Fan/Fan motor
Q'ty...Dia. and length
mm
Fan motor model...Q'ty
No. of poles...rpm (220V, High)
Nominal output
W
Coil resistance (Ambient temp. 20˚C)
Ω
Safety devices
Type
Operating temp. Open
˚C
Close
˚C
Run capacitor
µ
F
VAC
Cross-flow /AC motor
1... D100
KFG4X-31B6P-S...1
4...1269
30
Thermal protector
130
*
8
79
*
15
1.5
480
BRN-WHT: 161.2
WHT-VLT : 11.6
VLT-ORG : 68.7
ORG-YEL: 26.9
YEL-BLK : 22.8
BLK-PNK : 115.2