3-7. Wiring Instructions for Inter-unit Connections
25 cm
Wiring
Rear
panel
Plastic
cover
Fig. 25
Cover
Fig. 26a
Fig. 27
(SAP-KMRV74, KMRV94, KMRV124)
(SAP-KRV184, KRV244)
Fig. 24b
(SAP-KRV96)
Fig. 24a
Fig. 26b
(SAP-KRV96)
(1) Grasp both ends of the air intake grille, and
remove it by opening towards the front and
pulling towards you.
(2) Remove the screw on the right side cover
plate and open the cover.
(Fig. 24a, 24b, 24c or 24d)
(3) Insert the inter-unit wiring into the through-
the-wall PVC pipe. Lead the power wiring
into the room allowing approx. 25 cm to
extend from the wall face. (Fig. 25)
(4) Route the inter-unit wiring from the back of
the indoor unit and pull it towards the front
for connection. (Fig. 26a, 26b, 26c or 26d)
(5) Connect the inter unit wiring to the corre-
sponding terminals on the terminal plate
(Fig. 26a, 26b, 26c or 26d) while referring
to the wiring diagram.
(6) Be sure to secure the wiring with the pro-
vided clamp.
When closing the air intake grille, press the bot-
tom right and left corners and center. (Fig. 27)
Please refer to “How to replace the grille” on
page 8, 9, 10, 11 or 12 for installing the air
intake grille.