This projector uses a high-pressure lamp which must be handled carefully and properly. Improper handling
may result in accidents, injury, or create a fire hazard.
●
Lamp lifetime may differ from lamp to lamp and according to the environment of use. There is no
guarantee of the same lifetime for each lamp. Some lamps may fail or terminate their lifetime in a shorter
period of time than other similar lamps.
●
If the projector indicates that the lamp should be replaced, i.e., if the LAMP REPLACE INDICATOR lights
up, replace the lamp with a new one IMMEDIATELY after the projector has cooled down.
( Follow carefully the instructions in the LAMP REPLACEMENT section of owner's manual. ) Continuous
use of the lamp with the LAMP REPLACE INDICATOR lighted may increase the risk of lamp explosion.
●
A Lamp may explode as a result of vibration, shock or degradation as a result of hours of use as its
lifetime draws to an end. Risk of explosion may differ according to the environment or conditions in which
the projector and lamp are being used.
IF A LAMP EXPLODES, THE FOLLOWING SAFETY PRECAUTIONS SHOULD BE TAKEN.
If a lamp explodes, disconnect the projector’s AC plug from the AC outlet immediately. Contact an
authorized service station for a checkup of the unit and replacement of the lamp. Additionally, check
carefully to ensure that there are no broken shards or pieces of glass around the projector or coming out
from the cooling air circulation holes. Any broken shards found should be cleaned up carefully. No one
should check the inside of the projector except those who are authorized trained technicians and who are
familiar with projector service. Inappropriate attempts to service the unit by anyone, especially those who
are not appropriately trained to do so, may result in an accident or injury caused by pieces of broken glass.
LAMP HANDLING PRECAUTIONS
- 12 -
Lamp replacement
You can check the lamp used time and projector used time following to below
procedure.
1
Enter special menu mode.
Press and hold
POWER ON-OFF
button on the side control of the projector
or the remote control unit for more than 20 seconds.
Press point Up(
) and DOWN (
)buttons to select "Counter" and than
press "SELECT" button.
2
The projector used time and lamp used time will be displayed on the screen.
3
Press Power button "ON-OFF" once and close the special menu mode.
The LAMP REPLACE indicator will light yellow when the total lamp used time
reaches 2,000 hours - (
✽
). This is to indicate that lamp replacement is
required.
(
✽
) The specification is subject to change without notice.
Special
Counter
Fan control
RS232C
Counter
123H
123H
123H
123H
123H
Projector
Lamp 1
Lamp 2
Lamp 3
Lamp 4
●
How to check Lamp Used Time
Summary of Contents for PLV-HD2000E
Page 109: ... 109 IC Block Diagrams ICS1523M Clock Driver IC8209 CXA2151Q RGB Matrix IC271 ...
Page 166: ... 166 MEMO ...
Page 167: ... 167 MEMO ...
Page 168: ... PLV HD2000N E JUL 2006 BB 350 Printed in Japan SANYO Electric Co Ltd ...
Page 194: ...A26 PCB_MA4A BGA side A FANNET_3 K16W MAIN K8L MAIN K401 MAIN K8K MAIN K2203 BGA side B ...
Page 196: ...A28 PCB_MA4A ...
Page 198: ...Diagrams Drawings MA4 HD2000N00 PA4 HD2000E00 ...