- 50 -
A
A
A
A
A
A
18
Optical Filters and Lenses removal.
1. Remove Optical filter (UV/IR), remove the Condenser lens (IN), remove the Condenser lens (OUT), remove the Relay
lens (IN), remove the Optical filter (UV cut), remove the Condenser lens (R-FIL), remove the Condenser lens (UV-FIL), and
remove the Condenser lens (G) upward.
Note : Do not touch optical filters and lenses surface directly with hand.
Mark the mirrors as they are removed from the optical unit so that they may be reassembled in the location and
direction from which they were removed.
19
Optical base BTM disassemblies.
1. Remove 6 screws-A, remove the Optical Base BTM-A and the Optical Base BTM-B disassemblies.
Lens condensor (UV / FIL)
Optical base BTM-A
Optical Unit disassemblies
Optical base BTM-B
Lens condensor (OUT)
Lens condensor (G)
Lens condensor (R-FIL)
Optical filter (UV / IR)
Lens condensor (IN)
Lens relay (IN)
Lens relay (IN)
Arrow mark comes
this figure.
Summary of Contents for PLC-XF47
Page 153: ... 153 Mecanical and Optical Parts 53 72 68 52 118 120 126 55 54 69 69 70 70 101 123 ...
Page 154: ... 154 Mecanical and Optical Parts 102 103 115 114 114 121 121 125 112 119 118 122 117 ...
Page 155: ... 155 Mecanical and Optical Parts 71 116 71 116 116 116 111 80 111 110 110 78 81 79 ...
Page 195: ... 195 ...
Page 196: ...SM5110880 PLC XF47 SEP 2007 BB 350 Printed in Japan ...
Page 218: ......