- 39 -
A
A
B
B
D
D
D
D
C
C
C
C
Temperature switch
SW904
10
-3 Fan(FN915), Ducts, and Temperature switches removal.
1. Remove 2 screws-A and remove the Fan(FN915).
2. Remove 2 screws-B and remove the Duct PBS.
3. Remove 4 screws-C and remove the Ducts.
4. Remove 4 screws-D, remove the 4 temperature switches (SW903,SW904,SW905,SW906) and 4 sheets.
Mechanical disassemblies
B
B
A
A
B
C
C
C
10
-4 Holders removal.
Note;
Mark the temperature switches as they are
removed from the optical base so that they may
be reassembled in the same location from which
they were removed.
1. Remove 2 screws-A, remove 3 screws-B and remove the Holder-A.
2. Remove 3 screws-C and remove the Holder-B.
Temperature switch
SW903
Temperature switch
SW905
Temperature switch
SW906
Sheet
Duct PBS
FN915
Holder-A
Holder-B
Duct
Duct