- 91 -
Electrical Adjustments
Caution
:
Other adjustment items are not related to
service and a maintenance. Don't change
the data values of those adjustment items.
Otherwise it may cause loss of product safety.
Note :
Group No. 930
n
If the data value appears "11" on the screen, the lamp mode is
selected.
n
If the data value appears "0" on the screen, the lamp mode is
not selected. Set the data value to "10."
n
If the data value appears "99" on the screen, it is period for
cooling of the lamp. Wait until it is changed to "0." Then set
the data value to "10."
Note : Fans control Group No. 140
Group Fans A: FN903, 904, 905, 916
Group Fans B:
FN906, 907,908, 913
914, 915
Group Fans C:
FN909, 910, 911, 912
Group Fans D:
FN917, 918, 919, 920
n
Test Points Location
Please refer to "Printed Wiring Board Drawings." for the locations of test point.
FN903
FN905
FN916
FN904
FN909
FN910
FN920
FN919
FN918
FN917
FN913
FN915
FN914
FN907
FN912
FN911
FN908
FN906