55
Turn off the projector, and unplug the AC power cord
from the AC outlet.
Turn over the projector and remove the air filters by
pulling the latches upward.
1
2
Air filters prevent dust from accumulating on the surface of the optical elements inside the projector. Should the
air filters become clogged with dust particles, they will reduce cooling fans’ effectiveness and may result in a
buildup of internal heat and adversely affect the life of the projector. Clean the air filters by following the steps
below.
Clean the air filters with a brush or rinse them softly.
When rinsing the air filters, dry them well.
3
Replace the air filters properly. Make sure that the air
filters are fully inserted.
4
CAUTION
Do not operate the projector with the air filters
removed. Dust may accumulate on the optical
elements degrading picture quality. Do not put
anything into the air intake vents. Otherwise it may
result in malfunction of the projector.
RECOMMENDATION
We recommend avoidin� dusty/smoky environments
when you operate the projector. Usa�e in these
environments may cause poor ima�e quality.
When you use the projector under dusty or smoky
conditions, dust may accumulate on the lens, LCD panels,
or optical elements inside the projector degrading the
quality of a projected image.
When the symptoms above are noticed, contact your
authorized dealer or service station for proper cleaning.
Note:
When reinserting the air filters, be sure that
the slit part is facing the outer side.
Cleanin� the Air Filters
Maintenance and Cleanin�
Be sure to reset the Filter counter after cleaning or replacing the filters.
Press the MENU button to display the On-Screen
Menu. Use the Point
◄►
buttons to move the red
frame pointer to the Setting Menu icon.
Use the Point
▲▼
buttons to move the red frame
pointer to Filter counter and then press the SELECT
button. A dialog box appears showing the total
accumulated time of the filter use, a timer setting
option, and the reset option. Select Reset and the
“Filter counter Reset?” appears. Select [Yes] to
continue.
1
Resettin� the Filter Counter
Filter counter
Another confirmation dialog box appears, select [Yes]
to reset the Filter counter.
Air filters
Pull up and remove.
Select Reset and
the “Filter counter
Reset?” appears.
Select [Yes],
then another
confirmation
box appears.
Select [Yes] again
to reset the Filter
counter.
Summary of Contents for PLC-WXE45