PLC-WM5500/WM5500L Expand Serial Command Functional Specifications
76/88
9.11.5 CR_LOGO Command
Command
“CR_LOGO” [CR]
Details
Get setting status of Logo
Acceptable
“000_%1” [CR]
%1
“DFLT” ----------------------------- Default Logo is enabled
“USER” --------------------------- User is enabled
“OFF” ------------------------------ Logo is disabled
Response
Unacceptable “Error Code” [CR]
9.11.6 CR_LOGOLOCK Command
Command
“CR_LOGOLOCK” [CR]
Details
Get setting status of Logo Lock function
Acceptable
“000_%1” [CR]
%1
“ON” --------------------------- Logo Lock is ON
“OFF” ------------------------- Logo Lock is OFF
Response
Unacceptable “Error Code” [CR]
9.11.7 CR_PIP Command
Command “CR_PIP” [CR]
Details
Get status of “Picture in Picture” setting
Acceptable
“000_%1” [CR]
%1
“OFF” -------------------- Off is selected
“USER1” ---------------- User1 is selected
“USER2” ---------------- User2 is selected
“USER3” ---------------- User3 is selected
“USER4” ---------------- User4 is selected
“USER5” ---------------- User5 is selected
Response
Unacceptable
“Error Code” [CR]
9.11.8 CR_PIPMODE Command
Command “CR_PIP” [CR]
Details
Get Mode in “Picture in Picture”
Acceptable
“000_%1” [CR]
%1
“PINP” ----------------- P in P is selected
“PBYP” ---------------- P by P is selected
Response
Unacceptable
“Error Code” [CR]