PLC-WM5500/WM5500L Expand Serial Command Functional Specifications
60/88
9.5.5
CR_V-POS Command
Command
“CR_V-POS” [CR]
Details
Get value of Vertical Position
Acceptable
“000_%1” [CR]
%1
“0000 – nnnn”
(nnnn = Total Line – Display area V)
Response
Unacceptable
“Error Code” [CR] ------ When command is not available in the
given condition (such as being selected input
“?” [CR] --------------------- When unknown command is received
9.5.6
CR_DDOTS Command
Command
“CR_DDOTS” [CR]
Details
Get value of Display Dots
Acceptable
“000_%1” [CR]
%1
“0100 – nnnn”
(nnnn = Total Dots – Position H)
Response
Unacceptable
“Error Code” [CR] ---- When command is not available in the
given condition (such as being selected input
“?” [CR] -------------------- When unknown command is received
9.5.7
CR_DLINE Command
Command
“CR_DLINE” [CR]
Details
Get value of Display Line
Acceptable
“000_%1” [CR]
%1
“0100 – nnnn”
(nnnn = Total Line – Position V)
Response
Unacceptable
“Error Code” [CR] ---- When command is not available in the
given condition (such as being selected input)
“?” [CR] -------------------- When unknown command is received