PLC-WM5500/WM5500L Expand Serial Command Functional Specifications
74/88
9.10 Sound Status Read Command
9.10.1 CR_VOLUME Command
Command
“CR_VOLUME” [CR]
Details
Get volume value by user control
* When input signal is Network, error code “101” is returned.
Acceptable
“000_%1” [CR]
%1
“000 – 063”
Response
Unacceptable “Error Code” [CR]
9.10.2 CR_MUTE Command
Command
“CR_MUTE” [CR]
Details
Get setting status of Sound Mute.
* When input signal is Network, error code “101” is returned.
Acceptable
“000_%1” [CR]
%1
“ON” -------------------------- Sound Mute is ON.
“OFF” ------------------------- Sound Mute is OFF.
Response
Unacceptable “Error Code” [CR]
9.10.3 CR_BLTINSP Command
Command
“CR_BLTINSP” [CR]
Details
Get setting status of Built- in speaker.
* When input signal is Network, error code “101” is returned.
Acceptable
“000_%1” [CR]
%1
“ON” ----------------- Built-in speaker is ON.
“OFF” --------------- Built-in speaker is OFF
Response
Unacceptable “Error Code” [CR]