background image

PLC-WM5500/WM5500L Expand Serial Command Functional Specifications

 

2/88

 

  Contents 

Overview ......................................................................................................................9 

Serial Interface Specification ....................................................................................9 

2.1 

Transfer Specification ............................................................................................9 

2.2 

Connection ..............................................................................................................9 

Notes for communication ........................................................................................10 

Notation Convention ................................................................................................10 

Functional Execution Command Table ..................................................................11 

5.1 

Image Command Table.........................................................................................11 

5.2 

PC Adjust Control Command Table ....................................................................11 

5.3 

Input Control Command Table ............................................................................11 

5.4 

Screen Control Command Table .........................................................................12 

5.5 

Lamp Command Table..........................................................................................12 

5.6 

Sound Command Table ........................................................................................12 

5.7 

Setting Command Table .......................................................................................12 

5.8 

Other Command Table..........................................................................................13 

Status Read Command Table ..................................................................................14 

6.1 

Image Status Read Command Table ...................................................................14 

6.2 

PC Adjust Status Read Command Table ............................................................14 

6.3 

Video Status Read Command Table....................................................................14 

6.4 

Input Status Read Command Table.....................................................................14 

6.5 

Screen Status Read Command Table .................................................................15 

6.6 

Lamp Status Read Command Table....................................................................15 

6.7 

Sound Status Read Command Table ..................................................................15 

6.8 

Setting Status Read Command Table .................................................................15 

6.9 

Other Status Read Command Table....................................................................16 

Error Code Table.......................................................................................................17 

Functional Execution Command ............................................................................18 

8.1 

Format ....................................................................................................................18 

8.2 

Transfer Example ..................................................................................................18 

8.3 

Operation Requirements ......................................................................................18 

8.4 

Image Command ...................................................................................................19 

8.4.1 

CF_ BRIGHT Command........................................................................................19 

8.4.2 

CF_CONT Command ............................................................................................19 

8.4.3 

CF_COLOR Command..........................................................................................19 

8.4.4 

CF_TINT Command...............................................................................................19 

8.4.5 

CF_SHARP Command ..........................................................................................20 

8.4.6 

CF_GAMMA Command.........................................................................................20 

8.4.7 

CF_WBAL- Command...........................................................................................20 

8.4.8 

CF_COLTEMP Command .....................................................................................21 

Summary of Contents for PLC-WM5500

Page 1: ...EXPAND SERIAL COMMAND FUNCTIONAL SPECIFICATIONS PLC WM5500 PLC WM5500L Ver 1 00 SANYO Electric Co Ltd DS Company Projector Division ...

Page 2: ...d Command Table 14 6 1 Image Status Read Command Table 14 6 2 PC Adjust Status Read Command Table 14 6 3 Video Status Read Command Table 14 6 4 Input Status Read Command Table 14 6 5 Screen Status Read Command Table 15 6 6 Lamp Status Read Command Table 15 6 7 Sound Status Read Command Table 15 6 8 Setting Status Read Command Table 15 6 9 Other Status Read Command Table 16 7 Error Code Table 17 8 ...

Page 3: ...TORE Command 27 8 5 11 CF_PCMODEFREE Command 28 8 6 Input Control Command 29 8 6 1 CF_INPUT Command 29 8 6 2 CF_SOURCE Command 29 8 6 3 CF_INPUT 1 Command 30 8 6 4 CF_INPUT 2 Command 30 8 6 5 CF_INPUT 3 Command 30 8 6 6 CF_INPUT 4 Command 30 8 6 7 CF_SYSTEM Command 31 8 7 Screen Control Command 32 8 7 1 CF_SCREEN Command 32 8 7 2 CF_DZCENT Command 32 8 7 3 CF_VSCALE Command 33 8 7 4 CF_VPOS Comman...

Page 4: ...IP Command 42 8 10 8 CF_PIPMODE Command 42 8 10 9 CF_PIPMAININP Command 43 8 10 10 CF_PIPSUBINPU Command 43 8 10 11 CF_PIPSIZE Command 43 8 10 12 CF_PIPPOSITION Command 44 8 10 13 CF_PIPFRAMELOCK Command 44 8 10 14 CF_PIPSTORE Command 44 8 10 15 CF_PIPMODEFREE Command 45 8 10 16 CF_PIPRST Command 45 8 10 17 CF_ HDMI SETUP Command 45 8 10 18 CF_HDMI SOUND Command 45 8 10 19 CF_FILH Command 46 8 10 ...

Page 5: ...Command 52 8 11 Other Commands 53 8 11 1 CF_KEYEMU Command 53 8 11 2 CF_MENU Command 53 8 11 3 CF_POWER Command 54 8 11 4 CF_FREEZE Command 54 8 11 5 CF_VMUTE Command 54 9 Status Read Command 55 9 1 Format 55 9 2 Transfer Example 55 9 3 Operation Condition 55 9 4 Image Status Read Command 55 9 4 1 CR_BRIGHT Command 55 9 4 2 CR_CONT Command 55 9 4 3 CR_COLOR Command 55 9 4 4 CR_TINT Command 56 9 4 ...

Page 6: ... 7 Input Read Command 64 9 7 1 CR_INPUT Command 64 9 7 2 CR_SOURCE Command 64 9 7 3 CR_SRCINP1 Command 64 9 7 4 CR_SRCINP2 Command 64 9 7 5 CR_SRCINP3 Command 65 9 7 6 CR_SRCINP4 Command 65 9 7 7 CR_SYSTEM Command 66 9 7 8 CR_SYSLIST Command 67 9 7 9 CR_MODELIST Command 67 9 7 10 CR_HMSLOT Command 68 9 7 11 CR_NMSLOT1 Command 68 9 7 12 CR_NMSLOT2 Command 68 9 7 13 CR_NMSLOT3 Command 68 9 7 14 CR_N...

Page 7: ...ME Command 74 9 10 2 CR_MUTE Command 74 9 10 3 CR_BLTINSP Command 74 9 11 Setting Status Read Command 75 9 11 1 CR_LANG Command 75 9 11 2 CR_INPUTBUTTON Command 75 9 11 3 CR_DISP Command 75 9 11 4 CR_BACKGND Command 75 9 11 5 CR_LOGO Command 76 9 11 6 CR_LOGOLOCK Command 76 9 11 7 CR_PIP Command 76 9 11 8 CR_PIPMODE Command 76 9 11 9 CR_PIPMAININP Command 77 9 11 10 CR_PIPSUBINPU Command 77 9 11 1...

Page 8: ...ommand 82 9 11 34 CR_KEYDIS Command 82 9 11 35 CR_SECURITY Command 82 9 11 36 CR_PJLOCKNOW Command 83 9 11 37 CR_PJLOCKMENU Command 83 9 11 38 CR_SHUTRCPROT Command 83 9 11 39 CR_SHUTKEYPROT Command 83 9 11 40 CR_SHUTH Command 84 9 11 41 CR_CCAPTIONDISP Command 84 9 11 42 CR_CCAPTIONCOLOR Command 84 9 11 43 CR_DELAYCTRL Command 84 9 11 44 CR_TESTPAT Command 85 9 12 Other Status Read Commands 86 9 ...

Page 9: ... Serial Commands 2 Serial Interface Specification 2 1 Transfer Specification Item Specification Synchronous System Asynchronous Transmission Speed 9600 19200 Data Length 8 bits Parity N A Stop Bit 1 Flow Control N A Note1 Transmission Speed initial setting value is 19200 Note2 Transmission Speed can be changed in Service mode 2 2 Connection Dedicated serial cables must be used for the connection b...

Page 10: ...PC Projector CF_BRIGHT_032 CR Next command Projector PC 000 CR Return Value A few ms 5s 5 Do not send another command before the reception of the return value the operation by the command is not ensured However this is not the case when no response is returned after more than 5 seconds 6 It takes about 5 seconds for internal initialization after plugging in AC power During this time it cannot proc...

Page 11: ...t 5 2 PC Adjust Control Command Table Execute command Item CF_FSYNC_ 1 CR Set value of Fine Sync CF_TDOTS_ 1 CR Set value of Total Dots CF_CLPPHASE_ 1 CR Set value of Clamp Phase CF_H POS_ 1 CR Set value of Horizontal Position CF_V POS_ 1 CR Set value of Vertical Position CF_DDOTS_ 1 CR Set value of Display Dots CF_DLINE_ 1 CR Set value of Display Line CF_SETPCADJ_ 1 CR Apply values set in PC Adju...

Page 12: ...ilt in speaker 5 7 Setting Command Table Execute command Item CF_LANG_ 1 CR Select language for OSD CF_MENUPOSITION_ 1 CR Select the position of the On Screen Menu CF_INPUTBUTTON_ 1 CR Set up Input search function CF_DISP_ 1 CR Set ON OFF of On Screen Display CF_BACKGND_ 1 CR Select screen for no signal CF_LOGO_ 1 CR Set PIN code and mode for Logo CF_PIP_ 1 CR Set Picture in Picture CF_PIPMODE_ 1 ...

Page 13: ...for count down mode in P timer function CF_KEYDIS_ 1 CR Prohibit RC KEY control CF_PJPINCODE_ 1 CR Enter PJ PIN code to cancel PJ lock CF_SHUTRCPROT_ 1 CR Set valid invalid of RC use on Shutter control function CF_SHUTKEYPROT_ 1 CR Set valid invalid use of key on the top panel on Shutter control function CF_SHUTH_ 1 CR Set time of operating shutter management function CF_CCAPTIONDISP_ 1 CR Set cha...

Page 14: ... phase CR_H POS CR Get setting value of Horizontal Position CR_V POS CR Get setting value of Vertical Position CR_DDOTS CR Get setting value of Display Dots CR_DLINE CR Get setting value of Display Line CR_ORGMODE CR Get the original signal for PC Adjusted mode CR_PCSTORE CR Get status Free Stored for PC Adj mode 1 10 CR_SETPCADJ CR Get currently displayed PC signal in system 6 3 Video Status Read...

Page 15: ... running time of projector CR_HMLAMP CR Get the total number of lamps CR_LAMPLIFECONTRL CR Get selected mode in Lamp life control function 6 7 Sound Status Read Command Table Status Read command Item CR_VOLUME CR Get value of Volume CR_MUTE CR Get setting status of Sound Mute CR_BLTINSP CR Get setting status of Built in speaker 6 8 Setting Status Read Command Table Status Read command Item CR_LANG...

Page 16: ...ting time for count down mode in P timer CR_KEYDIS CR Get RC KEY prohibited status CR_SECURITY CR Get setting status of Security CR_PJLOCKNOW CR Get setting status of current PJ Lock CR_PJLOCKMENU CR Get PJ Lock setting status on the menu CR_SHUTRCPROT CR Get remote controller disability status of the shutter CR_SHUTKEYPROT CR Get Key controller disability state of the shutter CR_SHUTH CR Get time...

Page 17: ...selected Mode 102 Selected value is out of range Not reflected 103 Command mismatched to Hardware the command is for Optional function which is not implemented 201 Incremented or decremented value or values are beyond upper or lower limits 301 Not executable due to screen capturing in process Prompting reissue of the command after a while 402 Not executable due to PIN code in operation Prompting r...

Page 18: ...ommand PC PJ CF_TDOTS_1344 CR PC PJ 000 CR Acceptable 8 3 Operation Requirements 1 Functional Execution Command is limited when the projector status is as below However Status Read Command is still effective under following conditions Projector Status Available Functional Execution Command Standby Mode C00 Power ON CF POWER ON Countdown in process C00 Power ON CF POWER ON Terminates Count Down Coo...

Page 19: ...ore when the power is turned to ALL OFF status the value returns to the original setting It is stored in Suspend mode Acceptable 000 CR Response Unacceptable Error Code CR 8 4 3 CF_COLOR Command Command CF_COLOR_ 1 CR 1 000 063 Directly specify setting value of Color UP Increment setting value of Color by 1 DN Decrement setting value of Color by 1 Details Set user controlled value of Color Availab...

Page 20: ... Details Set user controlled value of Gamma Available only in the normal Power ON status The value set by this command will not be stored in the projector s memory Therefore when the power is turned to ALL OFF status the value returns to the original setting It is stored in Suspend mode Acceptable 000 CR Response Unacceptable Error Code CR 8 4 7 CF_WBAL Command Command CF_WBAL 1_ 2 CR 1 R RED G GR...

Page 21: ...ls Set value of Color specified in 1 of Offset Available only in the normal Power ON status The value set by this command will not be stored in the projector s memory Therefore when the power is turned to ALL OFF status the value returns to the original setting It is stored in Suspend mode Acceptable 000 CR Response Unacceptable Error Code CR 8 4 10 CF_NZRED Command Command CF_NZRED_ 1 CR 1 OFF Ca...

Page 22: ...splay graphic image with natural tone NATURAL Natural Fixed value to provide image with more natural color and tone CINEMA Cinema Fixed value to focus on tone reproduction for movie CUSTOM1 Image1 the value adjusted and stored by user CUSTOM2 Image2 the value adjusted and stored by user CUSTOM3 Image3 the value adjusted and stored by user CUSTOM4 Image4 the value adjusted and stored by user CUSTOM...

Page 23: ... value to Image 6 STR7 Store current adjusted value to Image 7 STR8 Store current adjusted value to Image 8 STR9 Store current adjusted value to Image 9 STR10 Store current adjusted value to Image 10 Details Reset or Store adjusted value for Image Available only in the normal Power ON status STR1 STR10 corresponds to Image1 Image10 displayed in projector OSD menu on selecting Store for adjusted va...

Page 24: ...cates maximum value which is less than 140 MHz in Dot Clocks UP Increment setting value of Total Dots by 1 DN Decrement setting value of Total Dots by 1 Details Set value of Total Dots in PC signal Available only in the normal Power ON status The value set by this command will not be stored in the projector s memory Therefore when the power is turned to ALL OFF status the value returns to the orig...

Page 25: ...ion by 1 DN Decrement setting value of Vertical Position by 1 Details Set Vertical Position value Available only in the normal Power ON status The value set by this command will not be stored in the projector s memory Therefore when the power is turned to ALL OFF status the value returns to the original setting Acceptable 000 CR Response Unacceptable 101 CR When input is Video signal When input is...

Page 26: ...is turned to ALL OFF status the value returns to the original setting Acceptable 000 CR Response Unacceptable 101 CR When input is Video signal When input is no signal 8 5 8 CF_SETPCADJ Command Command CF_SETPCADJ_ 1 CR 1 None EXT11 60 Details 1 Apply setting value of PC adj to the projecting image Projecting image can be corrected with this command as well as when PC control command and Screen co...

Page 27: ...gs such as whether or not to get PC signal through IP Available only in the normal Power ON status Note To differentiate between 60Hz and 50Hz in 1080i and 720p 60 or 50 is necessary to add to the parameter in this command Acceptable 000 CR Response Unacceptable 101 CR When input isn t PC analog 8 5 10 CF_PCSTORE Command Command CF_PCSTORE_ 1 CR 1 1 Store current value of PC Adjust to Mode1 2 Stor...

Page 28: ...to Free status 6 Set Mode6 to Free status 7 Set Mode7 to Free status 8 Set Mode8 to Free status 9 Set Mode9 to Free status 10 Set Mode10 to Free status Details Delete the data registered in Custom Mode1 10 and returns it to Free status This command operates the same way as storing to Mode1 10 in PC Adjust Menu Available only in the normal Power ON status Acceptable 000 CR Response Unacceptable 101...

Page 29: ...103 When selecting Input4on a projector with PJ Net attached and power OFF It comes to 101 Acceptable 000 CR Response Unacceptable Error Code CR 8 6 2 CF_SOURCE Command Command CF_SOURCE_ 1 CR Input 1 ANALOG Select RGB PC Analog Input SCART Select RGB Scart input HDMI Select HDMI input UP Select in PC Analog Scart HDMI PC Analog order DN Select in PC Analog HDMI Scart PC Analog order Input 2 VIDEO...

Page 30: ...y in the normal Power ON status Acceptable 000 CR Response Unacceptable Error Code CR 8 6 5 CF_INPUT 3 Command Command CF_INPUT3_ 1 CR 1 VIDEO Select Composite Video Input S VIDEO Select S Video Input YPBPR Select Y Pb Pr Input Details Select Input 3 as well as Source specified in 1 Available only in the normal Power ON status Acceptable 000 CR Response Unacceptable Error Code CR 8 6 6 CF_INPUT 4 ...

Page 31: ...Select D 720p D 575P Select D 575p D 480P Select D 480p D 1080PSF 24 Select D 1080psf 24 D 1080PSF 25 Select D 1080psf 25 D 1080PSF 30 Select D 1080psf 30 Input is Y Pb Cb Pr Cr AUTO Select System Auto 1080P Select 1080p 1080I Select 1080i 1035I Select 1035i 720P Select 720p 575P Select 575p 480P Select 480p 575I Select 575i 480I Select 480i 1 Input is Video S Video AUTO Select System Auto NTSC Se...

Page 32: ...ect Natural wide mode CUSTOM Select Custom mode UP Select screen size with forward switching in possible range DN Select screen size with backward switching in possible range 1 Common in AV PC RST Reset Screen adjustment Details Select screen size Available only in the normal Power ON status When selected input does not include specified 1 error code 101 CR is returned and it is not executed Recei...

Page 33: ...ere is no signal detected projector returns 101 and the command does not execute Acceptable 000 CR Response Unacceptable Error Code CR 8 7 4 CF_VPOS Command Command CF_VPOS_ 1 CR 1 015 15 014 14 002 2 001 1 000 0 01 1 02 2 14 14 15 15 UP Increment setting value of Vposition by 1 DN Decrement setting value of Vposition by 1 Details Set V Position Available only in the normal Power ON status When th...

Page 34: ...ere is no signal detected projector returns 101 and the command does not execute Acceptable 000 CR Response Unacceptable Error Code CR 8 7 6 CF_HPOS Command Command CF_HPOS_ 1 CR 1 015 15 014 14 002 2 001 1 000 0 01 1 02 2 14 14 15 15 UP Increment setting value of Hposition by 1 DN Decrement setting value of Hposition by 1 Details Set H Position Available only in the normal Power ON status When th...

Page 35: ...available range error code 201 is returned and the operation is not executed Example 1 When the correction level of the right part has reached its upper limit and then the command RIGHT is received Example 2 When the upper part correction allows only another step and then the command FUP is received Acceptable 000 CR Response Unacceptable Error Code CR 8 7 8 CF_KYSTONMODE Command Command CF_KYSTNM...

Page 36: ...ge downwards LEFT Correct the vertical line of image to the left RIGHT Correct the vertical line of image to the right Details Correct the bottom left corner of the image Available in normal Power ON status only The correction starts with the first command received Projector returns error code 101 and no operation is made when exceeding the correction limit Acceptable 000 CR Response Unacceptable ...

Page 37: ... this command is stored in EEPROM and setting remains effective even after the power is turned to ALL OFF status Acceptable 000 CR Response Unacceptable Error Code CR 8 7 15 CF_REAR Command Command CF_REAR_ 1 CR 1 ON Set Rear to ON OFF Set Rear to OFF Details Set Cancel Rear mode Available only in the normal Power ON status When Rear is ON projected image is left right reversed The status set by t...

Page 38: ...is command is stored in EEPROM and the setting remains effective after the power is turned to ALL OFF status Acceptable 000 CR Response Unacceptable Error Code CR 8 8 2 CF_LAMPLIFECONTRL_ Command Command CF_LAMPLIFECONTRL_ 1 CR 1 MODE1 Set Lamp life control to Mode 1 MODE2 Set Lamp life control to Mode 2 Details Select Lamp life control function Available only in the normal Power ON status The val...

Page 39: ...is stored in Projector s memory When input signal is Network error code 101 is returned Acceptable 000 CR Response Unacceptable Error Code CR 8 9 2 CF_MUTE Command Command CF_MUTE_ 1 CR 1 ON Set Sound Mute to ON OFF Set Sound Mute to OFF Details Control ON OFF of Sound Mute Available only in the normal Power ON status When input signal is Network error code 101 is returned Acceptable 000 CR Respon...

Page 40: ...CF_MENUPOSITION_ 1 CR 1 SET Move the menu display to next position Details Change the menu position Available in normal Power ON status only The position set by this command is stored in EEPROM and its setting is effective after ALL is OFF Position center bottom left bottom right top left top right center Menu display appears with the first command when menu display is not shown on the screen Acce...

Page 41: ...wer is turned to ALL OFF status Acceptable 000 CR Response Unacceptable Error Code CR 8 10 5 CF_BACKGND Command Command CF_BACKGND_ 1 CR 1 BLUE Select Blue Back USER Select User BLACK Select Black Back UP Switch forward Blue Back User Black Back Blue Back DN Switch backward Blue Back Black Back User Blue Back Details Set Screen status for no signal Available only in the normal Power ON status The ...

Page 42: ...ilable range Command is valid Acceptable PIN code is out of 1 available range Command is invalid Error code Note When Logo Lock is enabled matching Logo PIN code switches Logo but Logo Lock is not cancelled Lock status is kept When 2 USER is received error code 101 is returned in the case of Capture non practice Acceptable 000 CR Response Unacceptable Error Code CR 8 10 7 CF_PIP Command Command CF...

Page 43: ...lect Y Pb Pr Input YCBCR Select Y Cb Cr Input SCART Select SCART Input HDMI Select HDMI Input Details Select input and source of Sub picture of Picture in Picture Valid only when in the normal Power ON status Acceptable 000 CR Response Unacceptable Error Code CR 8 10 11CF_PIPSIZE Command Command CF_PIPSIZE_ 1_ 2 CR 1 1 Set main picture size to 10 2 Set main picture size to 20 3 Set main picture si...

Page 44: ... Picture in Picture is set to Off return 101 CR Acceptable 000 CR Response Unacceptable Error Code CR 8 10 13CF_PIPFRAMELOCK Command Command CF_PIPFRAMELOCK_ 1 CR 1 MAIN Set to main picture SUB Set to sub picture Details Set Frame lock of Picture in Picture Valid only when in the normal Power ON status Acceptable 000 CR Response Unacceptable Error Code CR 8 10 14CF_PIPSTORE Command Command CF_PIPS...

Page 45: ...tting status Details Reset current setting status of Picture in Picture Available only in the normal Power ON status Acceptable 000 CR Response Unacceptable Error Code CR 8 10 17CF_ HDMI SETUP Command Command CF_ HDMI SETUP _ 1 CR 1 NORMAL Select Normal mode ENHANCED Select Enhanced mode Details Select image mode of HDMI setup The status set by this command is stored in EEPROM and its setting is e...

Page 46: ...ILCTL Command Command CF_FILCTL_ 1 CR 1 ROLL Execute operation of scroll of filter Details Execute operation of scroll of filter Acceptable 000 CR Response Unacceptable Error Code CR 8 10 22CF_FILSCRL Command Command CF_FILSCRL_ 1 CR 1 RST Reset Filter scroll counter Details Reset Filter scroll counter Acceptable 000 CR Response Unacceptable Error Code CR 8 10 23 CF_FANSPEED Command Command CF_FAN...

Page 47: ...tatus set by this command is stored in EEPROM and setting remains effective even after the power is turned to ALL OFF status Acceptable 000 CR Response Unacceptable Error Code CR 8 10 26 CF_RSENS Command Command CF_RSENS_ 1 CR 1 ALL Select top front and back receiver of projector FRONTTOP Select front and top receivers of projector BACKTOP Select only back and top receivers of projector FRONTBACK ...

Page 48: ...etails Set time of Power Management time Available only in the normal Power ON status The status set by this command is stored in EEPROM and setting remains effective even after the power is turned to ALL OFF status Acceptable 000 CR Response Unacceptable Error Code CR 8 10 29CF_STANDBYMODE Command Command CF_STANDBYMODE_ 1 CR 1 ECO Less standby electricity NORMAL Normal standby electricity Detail...

Page 49: ... normal Power ON status The status set by this command is stored in EEPROM and setting value remains effective even after the power is turned to ALL OFF status Acceptable 000 CR Response Unacceptable Error Code CR 8 10 33CF_PTIMER Command Command CF_PTIMER_ 1 CR 1 START Start P timer STOP Stop P timer RESTART Resume P timer RST Reset P timer EXIT Exit P timer function Details Select the status of ...

Page 50: ...ptable PIN code is out of 1 range Command is invalid Error code is 102 This command is only valid when PJ PIN code dialog is displayed to enter PIN code after Power is ON and Countdown is completed When PIN code lock is set to On1 it needs to send this command every time the projector is turned on Acceptable 000 CR Response Unacceptable Error Code CR 8 10 37CF_SHUTRCPROT Command Command CF_SHUTRCP...

Page 51: ...e status set with this command is stored in EEPROM and its setting is effective even after ALL is OFF This command is available in normal Power ON status Note Closed caption is available under conditions below Entered signal is appropriate Video NTSC signal of S video Component 480i and System is fixed to NTSC or 480i Acceptable 000 CR Response Unacceptable Error Code CR 8 10 41CF_CCAPTIONCOLOR Co...

Page 52: ...ponse Unacceptable Error Code CR 8 10 43CF_TESTPAT Command Command CF_TESTPAT_ 1 CR 1 COLOR Display Color bar GRAD1 Display 16step white black GRAD2 Display 16step white black GRAD3 Display 16step white black GRAD4 Display 16step white black WHITE Display all white BLACK Display all black CROSS Display Cross OFF Do not show test pattern display UP Switch forward DN Switch backward Details Execute ...

Page 53: ...CF_KEYEMU parameter When User menu is displayed function is carried out with having displayed User menu When User menu isn t displayed error code 000 is returned function is non practice 101 is not returned even if a command of CF_KEYEMU is transmitted when cursor moves to the item which cannot toggle at an edge of the main menu example Display main menu and move to second menu of Image adj Move a...

Page 54: ...jector status requires using Status Read command Details Set Power to ON OFF Acceptable 000 CR Response Unacceptable Error Code CR 8 11 4 CF_FREEZE Command Command CF_FREEZE_ 1 CR 1 ON Set Freeze to ON OFF Set Freeze to OFF UP Switch forward On Off On DN Switch backward On Off On The same operation for UP and DN as this model has only ON OFF Details Set Cancel Freeze function Available only in the...

Page 55: ...4 CR 9 3 Operation Condition 1 Basically it should be always operated 2 Status Read Commands are invalid when projector is in standby under Eco mode selected in Standby mode menu 9 4 Image Status Read Command 9 4 1 CR_BRIGHT Command Command CR_BRIGHT CR Details Get user controlled value of Brightness Acceptable 000_ 1 CR 1 000 063 Response Unacceptable Error Code CR 9 4 2 CR_CONT Command Command C...

Page 56: ...Get user controlled value of Sharpness Acceptable 000_ 1 CR 1 000 031 Response Unacceptable Error Code CR 9 4 6 CR_GAMMA Command Command CR_GAMMA CR Details Get user controlled value of Gamma Acceptable 000_ 1 CR 1 000 015 Response Unacceptable Error Code CR 9 4 7 CR_WBAL R Command Command CR_WBAL R CR Details Get user controlled Red value of White Balance Acceptable 000_ 1 CR 1 000 063 Response U...

Page 57: ...gh BLANK OSD Menu is blank Neither of Xlow Low Mid High Response Unacceptable Error Code CR 9 4 11 CR_OFFSET R Command Command CR_OFFSET R CR Details Get user controlled Red value of Offset Acceptable 000_ 1 CR 1 000 063 Response Unacceptable Error Code CR 9 4 12 CR_OFFSET G Command Command CR_OFFSET G CR Details Get user controlled Green value of Offset Acceptable 000_ 1 CR 1 000 063 Response Una...

Page 58: ... CR 9 4 16 CR_IMAGE Command Command CR_IMAGE CR Details Get image setting status Acceptable 000_ 1 CR 1 DYNAMIC Dynamic STAND Standard REAL Real NATURAL Natural CINEMA Cinema CUSTOM1 Image1 CUSTOM2 Image2 CUSTOM3 Image3 CUSTOM4 Image4 CUSTOM5 Image5 CUSTOM6 Image6 CUSTOM7 Image7 CUSTOM8 Image8 CUSTOM9 Image9 CUSTOM10 Image10 Response Unacceptable Error Code CR When the command is invalid due to co...

Page 59: ...play area H Position H nnnn Maximum value less than 140 MHz of Dot Clock Response Unacceptable Error Code CR When command is not available in the given condition such as being selected input CR When unknown command is received 9 5 3 CR_CLPPHASE Command Command CR_CLPPHASE CR Details Get value of Clamp Phase value Acceptable 000_ 1 CR 1 0000 0255 Response Unacceptable Error Code CR 9 5 4 CR_H POS C...

Page 60: ... 6 CR_DDOTS Command Command CR_DDOTS CR Details Get value of Display Dots Acceptable 000_ 1 CR 1 0100 nnnn nnnn Total Dots Position H Response Unacceptable Error Code CR When command is not available in the given condition such as being selected input CR When unknown command is received 9 5 7 CR_DLINE Command Command CR_DLINE CR Details Get value of Display Line Acceptable 000_ 1 CR 1 0100 nnnn nn...

Page 61: ...ignal is 10350i 720P60 Indicates signal is 720p60 720P50 Indicates signal is 720p50 575P Indicates signal is 575p 480P Indicates signal is 480p 575I Indicates signal is 575i 480I Indicates signal is 480i 1080PSF 24 Indicates signal is 1080psf 24 1080PSF 25 Indicates signal is 1080psf 25 1080PSF 30 Indicates signal is 1080psf 30 1080P24 Indicates signal is 1080p24 1080P25 Indicates signal is 1080p2...

Page 62: ... CR 1 When input signal is PC Analog VGA1 Indicates VGA1 is selected VGA2 Indicates VGA2 is selected XGA1 Indicates XGA1 is selected WXGA3 Indicates WXGA3 is selected 1080I Indicates 1080i is selected 1035I Indicates 10350i is selected 720P Indicates 720p is selected 575P Indicates 575p is selected 480P Indicates 480p is selected 575I Indicates 575i is selected 480I Indicates 480i is selected 1080...

Page 63: ...80PSF 24 1080psf 24Hz 1080P60 1080p 60Hz 1080P50 1080p 50Hz 1080P30 1080p 30Hz 1080P25 1080p 25Hz 1080P24 1080p 24Hz 1080I60 1080i 60Hz 1080psf 30Hz 1080I50 1080i 50Hz 1080psf 25Hz 1035I 1035i 720P60 720p 60Hz 720P50 720p 50Hz 575P 575p 480P 480p 575I 575i includes Composite signal such as PAL 480I 480i includes Composite signal such as NTSC NO_SIGNAL No signal When 1080psf30 or 1080psf25 is input...

Page 64: ...VIDEO S Video is selected YPBPR Y Pb Cb Pr Cr is selected NETWORK Network is selected Response Unacceptable Error Code CR When command is not available in the given condition such as being selected input CR When unknown command is received 9 7 3 CR_SRCINP1 Command Command CR_SRCINP1 CR Details Get Source of INPUT1 Acceptable 000_ 1 CR 1 ANALOG in PC Analog mode SCART in Scart mode HDMI in HDMI mod...

Page 65: ...in Video mode S VIDEO in S video mode YPBPR in Y Pb Cb Pr Cr mode Response Unacceptable Error Code CR 9 7 6 CR_SRCINP4 Command Command CR_SRCINP4 CR Details Get Source of INPUT4 Acceptable 000_ 1 CR 1 NETWORK With PJ Net attached and the power ON Response Unacceptable 101 CR With PJ Net attached and the power ON 103 CR With PJ Net unattached CR When unknown command is received ...

Page 66: ...icates D WXGA3 is selected D 1080I indicates D 1080i is selected D 1035I indicates D 1035i is selected D 720P indicates D 720p is selected D 575P indicates D 575p is selected D 480P indicates D 480p is selected D 1080PSF 24 indicates D 1080psf 24 is selected D 1080PSF 25 indicates D 1080psf 25 is selected D 1080PSF 30 indicates D 1080psf 30 is selected Error Code 101 CR is returned for no signal I...

Page 67: ...SF 25 D1080psf 25 is in the list D 1080PSF 30 D1080psf 30 is in the list When input is Y Pb Cb Pr Cr All possible systems in Menu including Auto are returned AUTO Auto is in the list 1080I 1080i is in the list 1035I 1035i is in the list 575I 575i is in the list 480I 480i is in the list When input is Video or S video All possible systems in Menu including Auto are returned AUTO Auto is in the list ...

Page 68: ...d CR_NMSLOT2 CR Details Get terminal information of Input2 Acceptable 000_ 1 CR 1 5BNC Response Unacceptable Error Code CR 9 7 13 CR_NMSLOT3 Command Command CR_NMSLOT3 CR Details Get terminal information of Input3 Acceptable 000_ 1 CR 1 VIDEO Response Unacceptable Error Code CR 9 7 14 CR_NMSLOT4 Command Command CR_NMSLOT4 CR Details Get terminal information of Input4 Acceptable 000_ 1 CR 1 NETWORK...

Page 69: ...Response Unacceptable Error Code CR 9 7 17 CR_IDSLOT3 Command Command CR_IDSLOT3 CR Details Get ID information of Input3 This command is to determine sources possible to input Acceptable 000_ 1 CR 1 51 On board 3BNC and S VIDEO Available source VIDEO S VIDEO YPBPR Response Unacceptable Error Code CR 9 7 18 CR_IDSLOT4 Command Command CR_IDSLOT4 CR Details Get ID information of Input4 This command i...

Page 70: ... selected input CR When unknown command is received 9 8 2 CR_VSCALE Command Command CR_VSCALE CR Details Get setting status of V scale Acceptable 000_ 1 CR 1 32 035 Response Unacceptable Error Code CR 9 8 3 CR_VPOS Command Command CR_VPOS CR Details Get setting status of V Position Acceptable 000_ 1 CR 1 15 015 Response Unacceptable Error Code CR 9 8 4 CR_HSCALE Command Command CR_HSCALE CR Detail...

Page 71: ...rn is blue OFF Test pattern is not displayed Response Unacceptable Error Code CR 9 8 8 CR_CEIL Command Command CR_CEIL CR Details Get setting status of Ceiling Acceptable 000_ 1 CR 1 ON Ceiling projection is enabled OFF Ceiling projection is disabled Response Unacceptable Error Code CR 9 8 9 CR_REAR Command Command CR_REAR CR Details Get setting status of Rear function Acceptable 000_ 1 CR 1 ON Re...

Page 72: ...ble Error Code CR 9 9 3 CR_LAMPCORRESPH Command Command CR_LAMPCORRESPH CR Details Get Lamp running time in hours return lamp running time multiplied by a coefficient not actual running time Acceptable 000_ 1 CR 1 00000 99999 Response Unacceptable Error Code CR 9 9 4 CR_LAMPMODE Command Command CR_LAMPMODE CR Details Get setting status of Lamp mode Acceptable 000_ 1 CR 1 NORMAL Lamp mode is Normal...

Page 73: ...se Unacceptable Error Code CR 9 9 7 CR_HMLAMP Command Command CR_HMLAMP CR Details Get total lamp number Acceptable 000_ 1 CR 1 001 Response Unacceptable Error Code CR 9 9 8 CR_LAMPLIFECONTRL Command Command CR_LAMPLIFECONTRL CR Details Get setting status of Lamp life control Acceptable 000_ 1 CR 1 MODE1 Lamp life control is Mode1 status MODE2 Lamp life control is Mode2 status Response Unacceptabl...

Page 74: ...de CR 9 10 2 CR_MUTE Command Command CR_MUTE CR Details Get setting status of Sound Mute When input signal is Network error code 101 is returned Acceptable 000_ 1 CR 1 ON Sound Mute is ON OFF Sound Mute is OFF Response Unacceptable Error Code CR 9 10 3 CR_BLTINSP Command Command CR_BLTINSP CR Details Get setting status of Built in speaker When input signal is Network error code 101 is returned Acc...

Page 75: ... Error Code CR 9 11 2 CR_INPUTBUTTON Command Command CR_INPUTBUTTON CR Details Get setting status of Input button Acceptable 000_ 1 CR 1 MODE1 Input button mode is Mode1 MODE2 Input button mode is Mode2 MODE3 Input button mode is Mode3 Response Unacceptable Error Code CR 9 11 3 CR_DISP Command Command CR_DISP CR Details Get setting status of Display Acceptable 000_ 1 CR 1 ON Display is ON CNTDWNOF...

Page 76: ...n Acceptable 000_ 1 CR 1 ON Logo Lock is ON OFF Logo Lock is OFF Response Unacceptable Error Code CR 9 11 7 CR_PIP Command Command CR_PIP CR Details Get status of Picture in Picture setting Acceptable 000_ 1 CR 1 OFF Off is selected USER1 User1 is selected USER2 User2 is selected USER3 User3 is selected USER4 User4 is selected USER5 User5 is selected Response Unacceptable Error Code CR 9 11 8 CR_P...

Page 77: ...ut1 is selected 2 Input2 is selected 3 Input3 is selected 2 ANALOG ANALOG RGB is selected VIDEO Video Input is selected S VIDEO S VIDEO Input is selected YPBPR Y Pb Pr Input is selected SCART SCART Input is selected HDMI HDMI Input is selected Response Unacceptable Error Code CR 9 11 11CR_PIPSIZE Command Command CR_PIPSIZE CR Details Get picture size for Picture in Picture Sub picture Acceptable 0...

Page 78: ... others are Free SSSSS All Stored Response Unacceptable Error Code CR 9 11 14CR_HDMI SETUP Command Command CR_HDMI SETUP CR Details Get status of Image mode in HDMI setup Acceptable 000_ 1 CR 1 NORMAL Image mode is Normal ENHANCED Image mode is Enhanced Response Unacceptable Error code CR 9 11 15CR_HDMI SOUND Command Command CR_ HDMI SOUND CR Details Get status of Sound mode in HDMI setup Acceptab...

Page 79: ...1 19CR_FILCOND Command Command CR_FILCOND CR Details Get status of filter clog Acceptable 000_ 1 CR 1 CLOG Filter is clogged WARN Filter is nearly clogged CLEAN Filter is not clogged Response Unacceptable Error Code CR 9 11 20CR_FILREPL Command Command CR_FILREPL CR Details Get status of Filter cleaning replacement time Acceptable 000_ 1 CR 1 1Y Filter Exchange time is over value of Filter Message...

Page 80: ...acceptable Error Code CR 9 11 24CR_RSENS Command Command CR_RSENS CR Details Get selected location of infrared remote receiver of remote control Acceptable 000_ 1 CR 1 ALL Select top front and back receiver of projector FRONTTOP Select front and top receiver of projector BACKTOP Select back and top receiver of projector FRONTBACK Select front and back receiver of projector FRONT Select only front ...

Page 81: ...01 030 1 to 30 minutes Response Unacceptable Error Code CR 9 11 28CR_STANDBYMODE Command Command CR_STANDBYMODE CR Details Get setting status of Standby mode Acceptable 000_ 1 CR 1 ECO Less standby electricity NORMAL Normal standby electricity Response Unacceptable Error Code CR 9 11 29CR_ON STA Command Command CR_ON STA CR Details Get Direct on setting status Acceptable 000_ 1 CR 1 ON Direct on i...

Page 82: ...ly suspended OFF Exit P timer function Response Unacceptable Error Code CR 9 11 33CR_PTIME Command Command CR_PTIME CR Details Get setting time for count down mode of P timer Acceptable 000_ a CR 1 001 180 1 to 180 minutes Response Unacceptable Error Code CR 9 11 34CR_KEYDIS Command Command CR_KEYDIS CR Details Get status of RC KEY valid or invalid Acceptable 000_ 1 CR 1 NONE RC and KEY both are v...

Page 83: ...ENU CR Details Get ON OFF setting status of PIN code lock on menu Acceptable 000_ 1 CR 1 ON1 PIN code lock ON 1 is set on the menu ON2 PIN code lock ON 2 is set on the menu OFF PIN code lock OFF is set on the menu Response Unacceptable Error Code CR 9 11 38CR_SHUTRCPROT Command Command CR_SHUTRCPROT CR Details Get status if Shutter can be controlled by R C Acceptable 000_ 1 CR 1 ON Shutter is not ...

Page 84: ...f CC1 CC1 is selected CC2 CC2 is selected CC3 CC3 is selected CC4 CC4 is selected Response Unacceptable Error Code CR 9 11 42CR_CCAPTIONCOLOR Command Command CR_CCAPTIONCOLOR CR Details Get selected color of Closed caption Acceptable 000 CR a COLOR Color is selected WHITE White is selected Response Unacceptable Error Code CR 9 11 43CR_DELAYCTRL Command Command CR_DELAYCTRL CR Details Get setting s...

Page 85: ... Acceptable 000_ 1 CR 1 COLOR Color bar is displayed GRAD1 16step white black is displayed GRAD2 16step white black is displayed GRAD3 16step white black is displayed GRAD4 16step white black is displayed WHITE All white is displayed BLACK All black is displayed CROSS Cross is displayed OFF Test pattern display is not displayed Response Unacceptable Error Code CR ...

Page 86: ...ailure 81 Standby after Cooling Down due to lamp failure 2C Cooling Down in process after Power Off due to Shutter management 8C Standby after Cooling Down due to Shutter management Response Unacceptable Error Code CR 9 12 2 CR_SIGNAL Command Command CR_SIGNAL CR Details Get status whether there is any signal or not Acceptable 000_ 1 CR 1 ON There is signal OFF There is no signal Response Unaccept...

Page 87: ...1 data then one space and sensor 2 data Last character in each data indicates the sensor s status F Exceeding critical temp abnormal temp W Approaching critical temp Warning temp S Sensor temp is safe Safe temp N Sensor detects no critical temp E Unable to return the temp data The example 1 shows that sensor 1 indicates 31 5 degrees and the temperature is abnormal sensor 2 indicates 35 2 degrees a...

Page 88: ... The first data indicates sensor 1 data then one space and sensor 2 data The example 1 shows that sensor 1 indicates 31 5 degrees and the temperature is abnormal sensor 2 indicates 35 2 degrees and the temperature is safe sensor 3 indicates 38 0 degrees and the temperature is approaching critical state When it cannot return the temperature data due to hardware error the last character is E as in _...

Reviews: