PLC-WM5500/WM5500L Expand Serial Command Functional Specifications
72/88
9.9 Lamp Status Read Command
9.9.1
CR_LAMPREPL Command
Command
“CR_LAMPREPL” [CR]
Details
Get information of Lamp Replacement time
Acceptable
“000_%1” [CR]
%1
“1Y” ----------------- indicates over lamp replacement time
“1N” ----------------- indicates under lamp replacement time
Response
Unacceptable “?” [CR]
9.9.2
CR_LAMPH Command
Command
“CR_LAMPH” [CR]
Details
Get Lamp running time (in hours)
* return actual lamp running time
Acceptable
“000_%1” [CR]
%1
“00000 - 99999”
Response
Unacceptable “Error Code” [CR]
9.9.3
CR_LAMPCORRESPH Command
Command
“CR_LAMPCORRESPH” [CR]
Details
Get Lamp running time (in hours)
*return lamp running time multiplied by a coefficient (not actual running time)
Acceptable
“000_%1” [CR]
%1
“00000 – 99999”
Response
Unacceptable “Error Code” [CR]
9.9.4
CR_LAMPMODE Command
Command
“CR_LAMPMODE” [CR]
Details
Get setting status of Lamp mode
Acceptable
“000_%1” [CR]
%1
“NORMAL” --------------- Lamp mode is Normal status
“ECO1” -------------------- Lamp mode is Eco1 status
“ECO2” -------------------- Lamp mode is Eco2 status
“AUTO” -------------------- Lamp mode is Auto status
Response
Unacceptable “?” [CR]
9.9.5
CR_LAMPSTS Command
Command
“CR_LAMPSTS” [CR]
Details
Get Lamp status
Acceptable
“000_%1” [CR]
%1
“1I” ------------------------ Lamp is ON
“1O” ---------------------- Lamp is OFF
“1X” ----------------------- Lamp Failure
Response
Unacceptable “Error Code” [CR]