-60-
Electrical Adjustment
Grp / No. Item
Function
Range
Initial
Note
18
Normal Fan1 Min
Fan Spinning Set at Normal (Min/Max) (0.1V)
0000-9990
120
120
120
120
19
Normal Fan1 Max
0000-9990
138
138
138
138
20
Normal Fan2 Min
0000-9990
90
90
115
115
21
Normal Fan2 Max
0000-9990
90
90
115
115
22
Normal Fan3,4 Min
0000-9990
70
70
70
70
23
Normal Fan3,4 Max
0000-9990
138
138
138
138
24
Normal Fan5 Min
0000-9990
95
95
95
95
25
Normal Fan5 Max
0000-9990
138
138
138
138
26
Normal Fan6 Min
0000-9990
60
60
60
60
27
Normal Fan6 Max
0000-9990
138
138
138
138
28
Normal Fan7 Min
0000-9990
65
65
65
65
29
Normal Fan7 Max
0000-9990
138
138
138
138
30
Normal Fan8 Min
0000-9990
80
80
80
80
31
Normal Fan8 Max
0000-9990
138
138
138
138
32
Eco Fan Control Min Temp
Temp Sensor Control Start/End Temp St Eco
20-100
31
31
31
31
33
Eco Fan Control Max Temp
20-100
38
38
38
38
34
Eco Fan1 Min
Fan Spinning Set at Eco (Min/Max) (0.1V)
0000-9990
110
110
110
110
35
Eco Fan1 Max
0000-9990
110
110
110
110
36
Eco Fan2 Min
0000-9990
138
138
138
138
37
Eco Fan2 Max
0000-9990
60
60
70
70
38
Eco Fan3,4 Min
0000-9990
55
55
55
55
39
Eco Fan3,4 Max
0000-9990
138
138
138
138
40
Eco Fan5 Min
0000-9990
75
75
75
75
41
Eco Fan5 Max
0000-9990
138
138
138
138
42
Eco Fan6 Min
0000-9990
50
50
50
50
43
Eco Fan6 Max
0000-9990
138
138
138
138
44
Eco Fan7 Min
0000-9990
50
50
50
50
45
Eco Fan7 Max
0000-9990
138
138
138
138
46
Eco Fan8 Min
0000-9990
70
70
70
70
47
Eco Fan8 Max
0000-9990
138
138
138
138
255
Fan Start/Cooling Setting
0
Fan1 Initial Volt
Fan Start Voltage (0.1V)
0-255
70
1
Fan2 Initial Volt
0-255
70
2
Fan3,4 Initial Volt
0-255
70
3
Fan5 Initial Volt
0-255
70
4
Fan6 Initial Volt
0-255
70
5
Fan7 Initial Volt
0-255
70
6
Fan8 Initial Volt
0-255
70
8
Cooling Time
Coolong Time Setting (x30 sec.) 1: 30 3: 90 15: 450
1-15
3
10
Temp Error Cooling Time
Cooling Time Setting When the Temp Error occurs (x30 sec.)
1: 30 3: 90 15: 450
1-15
3
11
OnStart Cooling Start Threshold
0-100
50
12
After shutdown cooling
Cooling Operation after Shut Down (0: No, 1: Yes)
0-1
1
13
Normal Fan2 Cooling Voltage
Cooling Fan Voltage of Fan2 at Normal x0.1V
0 - 255
50
50
50
50
14
Eco Fan2 Cooling Voltage
Cooling Fan Voltage of Fan2 at Eco x0.1V
0 - 255
50
50
50
50
259
Fan Air Pressure Setting
0
Press Source Range Low
Pressure Sensor Control Range (AD)
0-1024
637
1
Press Source Range High
0-1024
293
2
Press Fan Add Range High
Add Voltage (0.1V)
0 - 2000
0
3
Press Fan Add Range Low
0 - 2000
65
4
Temp C-A Upward High
Temp C-A Upward High
0 - 1000
31
5
Temp C-A Upward Low
Temp C-A Upward Low
0 - 1000
29
6
Temp C-A Downward High
Temp C-A Downward High
0 - 1000
20
7
Temp C-A Downward Low
Temp C-A Downward Low
0 - 1000
16
260
Auto Calibration (Common)
* Auto calibration
0
Execute Calibration
Execute Calibration when the Value is changed. (For PC White
100%)
0 - 1
0
1
Loop Count
Max Times of Calibration
1 - 30
8
2
Auto Status
Calibration Log (Read only)
0: Calibration End Correctly 1: On Adjusting 9: Calibration
Error
0 / 1 / 9
0
3
AutoWait
Waiting time
1 - 20
3
4
CHECK - Tolerance
Tolerance of Offset
1 - 255
4
5
Time out wait
Wait Time until Time out [sec.]
1 - 255
20
261
Auto Calibration (RGB)
PW392-AFE MDL <10bits>
Summary of Contents for PLC-HP7000L
Page 97: ... 97 IC Block Diagrams ISL51002 A D Converter IC2201 M62393 DAC IC7801 ...
Page 99: ... 99 IC Block Diagrams PW392 Scaler IC301 PW610 Keystone IC2301 ...
Page 100: ... 100 IC Block Diagrams TE7783 I O Expander IC4801 ...
Page 103: ... 103 Mechanical Parts List KY2 HP7000L00 Shutter assembly M08 ...
Page 149: ...Key No Part No Description Key No Part No Description KY2 HP7000L00 149 Electrical Parts List ...
Page 150: ... KY2AL Nov 2011 DC 50 Printed in Japan SANYO Electric Co Ltd ...