-42-
Electrical Adjustment
Circuit Adjustments
CAUTION: The each circuit has been made by the fine adjustment at factory. Do not attempt to adjust the following
adjustments except requiring the readjustments in servicing otherwise it may cause loss of performance
and product safety. Before taking these adjustments, turn the projector for more than 10 minutes to sta-
bilize the operation.
[Adjustment Condition]
●
Input signal
Analog Computer signal ..... 0.7Vp-p/75
W
terminated (XGA)
Composite Video signal ... 1.0Vp-p/75
W
terminated (NTSC / PAL)
Component Video signal .... 1.0Vp-p/75
W
terminated (480i, 480p, 720p, 1080i)
●
Image mode ........................ “Standard”
●
Advanced color .................... “Off”
●
Lamp mode......................... “Normal”
●
Screen .................................. “Normal”
Note:
* Please refer to “Service Adjustment Menu Operation” for entering the service mode and adjusting the service data.
x
Fan Voltages adjustment
Equipment
Digital voltmeter
1. Enter the service mode.
2. Change data values of each test point to adjust the fan
driving voltage.
Group No.
Test Point
Adjustment value
250 - 0
TPFN1
5.0 +0.1 -0Vdc
250 - 1
TPFN1
13.8 +0 -0.1Vdc
250 - 2
TPFN2
4.0 +0.1 -0Vdc
250 - 3
TPFN2
13.8 +0 -0.1Vdc
250 - 4
TPFN3
5.0 +0.1 -0Vdc
250 - 5
TPFN3
13.8 +0 -0.1Vdc
250 - 6
TPFN4
4.5 +0.1 -0Vdc
250 - 7
TPFN4
13.8 +0 -0.1Vdc
250 - 8
TPFN5
5.0 +0.1 -0Vdc
250 - 9
TPFN5
13.8 +0 -0.1Vdc
250 - 10
TPFN6
5.0 +0.1 -0Vdc
250 - 11
TPFN6
13.8 +0 -0.1Vdc
250 - 12
TPFN7
5.0 +0.1 -0Vdc
250 - 13
TPFN7
13.8 +0 -0.1Vdc
z
LCD panel L/R setting
There are two type( Type L, Type R) for the LCD/Prism
Assy. The adjustment data is stored in the memory IC
on the main board.
As the used type is indicated on the LCDpanel/prism
assy, perform this adjustment to match to its type indica-
tion.
1. Enter the service mode.
2. Check the data value. (290 - 0)
Group No.
Value Panel type
290 - 0
0
L
290 - 0
20 r
3. To change the set panel type, select 290-1.
Group No.
Value Panel type
290 - 1
0
L
290 - 1
10 Initial
290 - 1
20 r
The initial data of 290 -1 is "10". To set the value for Type
L, set the value to "0". To set the value for Type R, set the
value to "20". When the value set "0" or "20", it automati-
cally returns to initial data "10" after the setup.
White 100%
White 0%
16 steps gray scale pattern
8 color 100% full color bar
W
Y
C
G
M
R
B
BK
White 100%
White 0%
Summary of Contents for PLC-HP7000L
Page 97: ... 97 IC Block Diagrams ISL51002 A D Converter IC2201 M62393 DAC IC7801 ...
Page 99: ... 99 IC Block Diagrams PW392 Scaler IC301 PW610 Keystone IC2301 ...
Page 100: ... 100 IC Block Diagrams TE7783 I O Expander IC4801 ...
Page 103: ... 103 Mechanical Parts List KY2 HP7000L00 Shutter assembly M08 ...
Page 149: ...Key No Part No Description Key No Part No Description KY2 HP7000L00 149 Electrical Parts List ...
Page 150: ... KY2AL Nov 2011 DC 50 Printed in Japan SANYO Electric Co Ltd ...