![Sanyo PLC-HP7000L Service Manual Download Page 41](http://html.mh-extra.com/html/sanyo/plc-hp7000l/plc-hp7000l_service-manual_362287041.webp)
-41-
to enter the service mode
To enter the “Service Mode”, press and hold the
MeNu
and
SeLect
button
on the projector or remote control for
more than 3 seconds. The service menu appears on the screen as follows.
to adjust service data
Select the adjustment group no. by pressing the
MeNu
button
(increase) or
SeLect
button
(decrease), and
select the adjustment item no. by pressing the pointer
U
or
V
button
, and change the data value by pressing the
W
or
X
button
. Refer to the “Service Adjustment Data Table” for further description of adjustment group no., item
no. and data value.
to exit the service mode
To exit the service mode, press the
oN/StANd-BY button
.
Service Adjustment Menu Operation
Memory IC on the main board stores the data for the
service adjustments, and should not be replaced ex-
cept for the case of defective device.
If replaced, the re-adjustments are required following to
the “Electrical Adjustments”.
The data of lamp replacement counter is stored in the
Memory IC.
Please note that the lamp replace counter will be reset
when the memory IC is replaced.
(Lamp replace counter cannot be set to the previous
value.)
●
caution to memory Ic replacement
When memory IC is replaced with new one, the CPU
writes down the default data of the service adjustments
to the replaced ICs as the mentioned on the service ad-
justment table. As these data are not the same data as
factory shipped data, it should be required to perform
the re-adjustments following to the “Electrical Adjust-
ments”.
Please note that in this case the lamp replace counter
will be reset.
●
caution of Main Board replacement (in the case
memory Ic is not defective)
When the main board is replaced, memory IC should
be replaced with the one on previous main board. After
replacement, it should be required to perform the re-ad-
justments following to the “Electrical Adjustments”.
In this case, the value of lamp replace counter can be
kept as before.
Memory IC (IC1387) Replacement
Service Mode
Input
Video
Group
No.
Data
0
0
32
Ver. R 1.00
Data value
Item No.
Group No.
Electrical Adjustments
Summary of Contents for PLC-HP7000L
Page 97: ... 97 IC Block Diagrams ISL51002 A D Converter IC2201 M62393 DAC IC7801 ...
Page 99: ... 99 IC Block Diagrams PW392 Scaler IC301 PW610 Keystone IC2301 ...
Page 100: ... 100 IC Block Diagrams TE7783 I O Expander IC4801 ...
Page 103: ... 103 Mechanical Parts List KY2 HP7000L00 Shutter assembly M08 ...
Page 149: ...Key No Part No Description Key No Part No Description KY2 HP7000L00 149 Electrical Parts List ...
Page 150: ... KY2AL Nov 2011 DC 50 Printed in Japan SANYO Electric Co Ltd ...